Comelit AHPTZ10IRC Скачать руководство пользователя страница 1

 

 

 

DOME IR PTZ 4 IN 1 

ART. AHPTZ10IRC 

           

 

 

 

 

 

 

 

 

 

Please read this manual thoroughly before use and keep it for future reference 

 

 

 

 

Содержание AHPTZ10IRC

Страница 1: ...DOME IR PTZ 4 IN 1 ART AHPTZ10IRC Please read this manual thoroughly before use and keep it for future reference ...

Страница 2: ...g flash with arrowhead symbol within an equilateral triangle is intended to alert the user the presence of non insulated dangerous voltage within the product s enclosure that maybe of sufficient magnitude to constitute a risk of electric shock to different persons The exclamation point within an equilateral triangle is intended to alert the user the presence of important operating and maintenance ...

Страница 3: ... or disassemble any internal parts of the video camera to avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera 5 All electrical connections to the dome should be made in strict accordance with the attached labels and wiring instructions in this manual Failure to do so may damage the dome beyond repair and void the warranty 6 For outdoor installatio...

Страница 4: ...vicing is required when the device has been damaged in any way when liquid traces are present or the presence of loose objects is evident or if the device does not function properly or has received sever impact or has been dropped accidentally 11 Do not use this product under circumstances exceeding specified temperature and humidity ratings 12 Avoid pointing the camera directly to the sun or othe...

Страница 5: ...enu 9 4 1 Menu Index 9 4 2 System Information 10 4 3 Dome 11 4 3 1 Communication 11 4 3 2 IR Display 12 4 3 3 Guard Tours 13 4 3 4 A B Scan 14 4 3 5 Pan Scan 15 4 3 6 Park Action 15 4 3 7 Privacy Zone 16 4 4 Camera 18 4 5 Language 19 4 6 Display 19 4 7 Reset 20 5 Auto Temperature Control 21 Appendix I Anti lightning Anti surge 21 Appendix II Clean Transparent Cover 22 Appendix III Common Knowledge...

Страница 6: ...Copyright Statement 24 Indicates the functions with default protocol it might not function by using other protocols Indicates the optional functions only with certain models ...

Страница 7: ...zontal 180 Vertical 93 Auto control IR LED PWM A B Scan User programmable A B Scan Speed 01 64 speed setting available 360 Scan Speed 01 64 speed setting available Dwell Preset 01 60 sec interval Preset Points 220 Go to Preset Speed 200 sec Guard Tours 3 groups Guard Points Max 16 points dwell time user selectable Home Pos Time 1 60 mins available PWR on Action Restore as power up Pan scan A B sca...

Страница 8: ...screen menu the available language is English IR Output Power Consumption IR output power consumption can be set through the OSD after IR is turned on IR Standby Power Consumption After IR is turned on if there is no operation and this period is more than the IR standby time set the dome will be on the standby mode User can set the max IR standby power consumption through OSD IR Detection Time Tim...

Страница 9: ... changes in ambient light through moving and adjust automatically lens aperture to make the brightness of output image stable Users can through pressing OPEN or CLOSE iris adjusting keys manually adjust the aperture size to get the required picture brightness By controlling the keyboard up down left right or zoom to resume auto iris auto iris is recommended Auto recognize to Protocol and Module Th...

Страница 10: ...ult setting the dome support power up memory which improves the reliability and avoids repeated settings of the parameter Park Action If users don t operate the dome in set time it will automatically run preset specific mode pan scan A B scan park action cruise preserve action etc Zero Alignment There is a point specified as zero point When the dome is working the preset point is not accurate beca...

Страница 11: ...5 2 1 Product Dimension 2 2 Bracket Dimensions 2 2 1 Wall Ceiling Mount Bracket ...

Страница 12: ...6 2 3 Installation 2 4 Connection Connection of RS485 Before connecting please turn off the power and read carefully the instructions of all connected devices Fig 24 ...

Страница 13: ...fy the scene Press ZOOM button to make the lens closer and magnify the scene Focus After FOCUS button is pressed the object in vicinity will become clearer while the object far away will become ambiguous After FOCUS button is pressed the object far away will become clearer while the object in vicinity will be ambiguous Iris Press IRIS to gradually shrink the iris and decrease the image brightness ...

Страница 14: ...pan XXX XX tilt IR Display Display on the lower right corner of the screen means the dome is on IR mode means the IR is turned on The IR output power COMM Display Display the dome ID and baud rate on the top left corner of the screen Remark 1 Items with mean they have sub menu PRESET FUNCTION PRESET FUNCTION 33 Pan scan180 º 87 BLC off 34 Reset 88 Freeze on 79 Digital zoom on 89 Freeze off 80 Digi...

Страница 15: ...ome option 3 means editing the content of some option selected 4 When entering the setting page in menu it is useless to call preset 94 to exit the menu directly Such as the submenu SET in menu GUARD TOUR SET 4 OSD Menu 4 1 Menu Index ...

Страница 16: ...OL display the protocol of the dome DOME ID display the dome address COMM format Baud rate Check bit Data bit Start bit VERSION Version will update along with the product upgrading Remark protocol ID and COMM all can be set in menu COMM MAIN MENU SYSTEM DOME CAMERA LANGUAGE DISPLAY RESET EXIT SYSTEM MFG PROTOCOL AUTO DOME ID 001 COMM 2400 N 1 VERSION EXIT ...

Страница 17: ...VICE ID It is only and used to distinct from the ID of other domes DOME COMM IR DISPLAY GUARD TOURS A B SCAN PAN SCAN PARK ACTION PRIVACY ZONE ADVANCED EXIT COMM DEVICE ID CHECK ID 0000 TARGET ID 001 SOFT PROTOCOL AUTO BAUD RATE 2400BPS COMM RESET SAVE EXIT ...

Страница 18: ...e out of factory default of dome camera is hardware DIP set After the COMM is changed in menu it can t be effective until saved If needing to get hardware DIP set again run the COMM RESET 4 3 2 IR Display Fig 4 3 2 1 WORKING MODE Working mode has auto black white color selectable Default is auto TESTING TIME On IR auto working mode and the programmed time the IR will execute the programmed action ...

Страница 19: ...he illumination on level is more than the ambient light the picture will change to black the IR illumination will turn on automatically AMBIENT LIGHT Ambient light is a system data User can not change it manually It changes according to the environment all the time The data will refresh every time when user enter the OSD It is from 0 to 50 grade IR SWITCH ZOOM IR switch zoom is 1 10 grade selectab...

Страница 20: ... After deleting the present preset points all display as 0 While the exact preset point information doesn t be deleted So it is convenient for user to select the preset point needing to be guarded tour 4 3 4 A B Scan Fig 4 3 4 1 PRESET A On A B scan A point can be preset from 0 to 64 PRESET B On A B scan B point can be preset from 0 to 64 SCAN SPEED A B scan speed is 1 to 64 grade selectable DWELL...

Страница 21: ... 4 3 5 1 PAN SCAN SPEED Pan scan speed is 1 to 64 grade selectable INIT Reset the scan speed and tilt degree as default setting CALL Call the new setting 4 3 6 Park Action Fig 4 3 6 1 Fig 4 3 6 2 PARK MODE Park mode includes OFF Park action A B scan Pan scan guard tour01 guard tour02 guard tour03 and Preserve action PAN SCAN PAN SCAN SPEED 10 INIT CALL EXIT PARK ACTION PARK MODE OFF PARK TIME 01M ...

Страница 22: ...ion and save the settings CALL Call the new setting DELETE Delete the settings 4 3 7 Privacy Zone If camera support Fig 4 3 7 1 Fig 4 3 7 2 Fig 4 3 7 3 MASK NO Mask No depends on the number of the module supported The selective range of Sony is from 1 to 24 MASK Mask has on and off selectable SETTING Set the specific parameter of present mask NO and call preset 1 to save the settings Direction ope...

Страница 23: ...en will display the interface as Fig 4 3 7 3 4 3 8 Advanced Fig 4 3 9 1 PWR ON ACTION Power on action can be set as Memory A B scan Pan scan Park action Guard tour 01 Guard tour 02 Guard tour 03 and No action RATIO SPEED Ratio speed can be set as ON or OFF status AUTO FLIP Auto flip can be set as ON or OFF status OTHERS Set other options ADVANCED PWR ON ACTION MEMORY RATIO SPEED ON AUTO FLIP ON OT...

Страница 24: ... is on off selectable FOCUS Focus is auto and manual selectable IRIS Iris is auto and manual selectable BLC BLC is ON and OFF selectable FREEZE Video freeze is ON and OFF selectable Remark Only if those functions are available on the present module the user can use it CAMERA CAM AUTO ZOOM SPEED QUICK DIGITAL ZOOM OFF FOCUS AUTO IRIS AUTO BLC OFF FREEZE OFF EXIT ...

Страница 25: ...s the pan and tilt degree user can enable or disable it ACTION On the screen it displays the current action such as A B scan Call preset Save preset Call park action Pan scan etc User can enable or disable it IR IR can be set as ON or OFF means the dome is on IR mode means the IR is turned on The IR output power LANGUAGE LANGUAGE ENGLISH EXIT DISPLAY SYSTEM PAL P AND T ON ACTION ON IR ON DOME ID O...

Страница 26: ...unication information User can enable or disable it 4 7 Reset RESET DOME RESTART SYS DATA CAM DATA PRESET EXIT DOME RESTART CONFIRM Save data dome restart EXIT SYS DATA CONFIRM Factory default EXIT CAM DATA CONFIRM Factory default EXIT PRESET CONFIRM DEL ALL PRESETS CONFIRM 1 DEL 01 TO 16 CONFIRM 2 DEL 17 TO 32 CONFIRM 3 DEL 33 TO 48 CONFIRM 4 DEL 49 TO 64 EXIT ...

Страница 27: ...own along the roofline Way of sealed steel pipe buried wiring is used in the area which opened and steel pipe units grounded in one point Overhead wiring is absolutely prohibited In the strong thunderstorms area or areas with high induced voltage such as high voltage substations measure of installation of additional high power lightning protection equipment and lightning rod must be taken Lightnin...

Страница 28: ...dge on RS 485 Bus 1 Basic Feature of RS 485bus According to industry bus standard of RS 485 RS 485 bus is half duplex communication bus with the characteristic impedance of 120Ω whose maximum load capacity is 32 payloads including the master device and the controlled device 2 Mode of Connection and Terminal Resistance 2 1 Industry standard of RS485 bus requires that connection mode of daisy chain ...

Страница 29: ...n as per the instruction manual Noise after self testing Mechanical obstruction Verify and correct it Camera module is not installed correct Correct Low power Change the correct power supply Image is not stable Low power Check the power supply or make sure the power input is DC 12V Video cable is improperly contact Verify the contact of the video cable Image is blurring Camera is on manual focus C...

Страница 30: ... Therefore the company reserves the right to modify or improve the products described in this manual without notice The content of manual is offered according to the current state Unless applicable law otherwise specified the company does not make any kind of clear or tacit reassurance about the accuracy reliability and contents of this manual The company reserves the right to revise or recoup thi...

Отзывы: