8
standards on safety levels with respect to human exposure to RF and electromagnetic fields from 300KHz
to 100GHz.
D. Testing Specifications
1. Production Acceptance Test: Each unit will be required to "pass" production acceptance testing and a
"Final Test Report" will be generated to document results.
1.1 Production Acceptance Testing process shall include as a minimum: Complete
Parametric/Functional Tests covering: line regulation, calibration, linearity, burn-in, over-temp
test, open circuit test, MAX power test, harmonic distortion, AC ripple, and remote interface
tests. Data sheet for each generator to be shipped with unit.
E. Packaging & Shipping Specifications
1. Accessories Supplied
1.1 Final test results
1.2 Operating manual
2. Shipping
NOTE:
If there is a conflict between this document and customer Purchase Order then the latter
supersedes.
NOTE FOR REPAIRS:
Unless repairs have accessories included with them and have them listed on t he
Return Material Authorization (RMA) Tag, returned materials will not have to fulfill procedural
requirements for accessories.
III. Unpacking and Inspection
1.
Carefully unpack the unit and inspect for any obvious signs of physical damage that might have occurred
during shipment. Notify the shipping agent of any damage immediately.
2.
Check the outside of the unit for missing or loose mounting screws or broken parts.
3.
If there is shipping damage or the unit fails to operate properly upon receipt, report damage to the carrier
and Comdel immediately.
CAUTION
: Breaking the seal or removing the warranty decal from this unit will void the warranty. If internal
damage is suspected, contact factory for assistance.
IV. Maintenance
The CX600 is designed to operate unattended for long periods of time. Should periodic maintenance or service be
required, it should only be performed by qualified service persons. Contact the factory for maintenance or service
recommendations.