Trouble Shooting. 

 

Problem  

Causes  

Solution  

Turn on button doesn't 
work and machine cannot 
be opened 

1.The battery is over-used 
or damaged 
2.Failures of motor or 
circuit board 
3.The battery is not insert 
or inserted tightly 

Change battery or install 
battery again after it is 
fully charged. If still 
failed, send the machine 
to 
professional maintenance 
personal for repair 

Motor works, but no wire 
comes out 

1. Without wire coil or 
install non-designated wire 
coil 
2. The end of the wire is 
not straightened 

1. Insert designated wire 
coil 
2. Straighten the end of 
the wire 

The machine doesn't work 

1. Low battery 
2. The gearing is jammed 
3. Failures of motor or 
circuit board 

1. Fully charged the 
battery 
2. Open the gearing and 
take out the stuff 

The wire fail to be cut off 

Wear of the wire cut blade 
or wire guiding block 

Change the wire cut blade 
or wire guiding block 

Wire shifting: the wire is 
not in the right place of the 
jaw, which leads to tying 
failure 

The jaw is blocked, which 
will cause intervention of 
wire track. As a result, the 
wire does not come out in 
the right place. 

Adjust the tying angle and 
clean the obstacles in the 
wire track, so as to 
eliminate all interference 

Charger indicator light off 

The charger failures 

Replace it with a new 
charger 

Buzzer Alarm 

1. the machine does not 
be 
used after turn on the 
power switch over one 
minuter 
2. Run out of the battery. 

1.Switch off and restart the 
machine 
2.Fully charged the battery 
or change the battery 

 

 

 

Содержание 580A

Страница 1: ...580A www comcast sa com Automatic Cable Tying Machine 580A ...

Страница 2: ...580A www comcast sa com Contenido Regular Information 3 Technical parameters 5 Operation Instruction 6 Trouble Shooting 8 Maintenance 9 After sales Service 9 Safety Instructions 10 Special Remarks 11 ...

Страница 3: ...tached tool with internal placement of components such as controllers The tool could automatically complete all steps of cable strapping and could be widely used in the field of communication engineering working at height to replace traditional manual attached strapping cables The machine is mainly composed of five parts body special coil battery remote control and hand held lever ...

Страница 4: ...ing personnel and reduces safety accidents which can ensure the safety of personnel 3 Easy operation of the equipment Simple and convenient remote control it can be operated by one person independently which reduce the use of labor force Because of it can easy to be understand quick to be used the different cultural levels and different age groups of workers wide use it 4 Easy to carry In the trad...

Страница 5: ...ut 3 km attached Insulating rod It can insulate the voltage of 10 KV it consists of glass fiber reinforced plastic epoxy pipe The length is1 2 m Coated wire 110m per roll once tying length of 700 750mm once with attached to 2KM Remote control The distance is 20m it still effects through the tall wall Standard Accessories 1pc of Cable tying machine 2pcs of battery 1pc of charger 2pcs of coated wire...

Страница 6: ... fuselage In the power on mode Put our customized wire coil into the machine III Take out and straighten the end of the wire approx 10 15cm and slowly insert the wire into the plastic mouth until it is blocked Put the wire coil cover back and lock the lock buckle Attention the wire would fail to be sent if the end of the wire is not straightened IV Hold the wire with two fingers and push it forwar...

Страница 7: ...ill restore to working condition XI The wire guiding block is quick wear part so it is needing to be adjusted if necessary Loose the screw and adjust it to proper position see figure2 The proper diameter of the knot circle is 83 85mm XII Torque Adjusting see figure 3 Adjust torque when the knot tightness is improper Press the button to increase the torque when the knot is loose the factory setting...

Страница 8: ...ng is jammed 3 Failures of motor or circuit board 1 Fully charged the battery 2 Open the gearing and take out the stuff The wire fail to be cut off Wear of the wire cut blade or wire guiding block Change the wire cut blade or wire guiding block Wire shifting the wire is not in the right place of the jaw which leads to tying failure The jaw is blocked which will cause intervention of wire track As ...

Страница 9: ...regularly replace the wearing parts such as wire guiding block and blade After sales Service Three months guarantee or guarantee of 100000 times from delivery depends on the earlier arrival with 3 months guarantee for the battery not including the damage caused by using non designated wire coil charge and battery Damages caused by man made or natural disasters are not included Wear parts such as c...

Страница 10: ...the machine in the dry and clean environment without corrosive gas when not in service 5 Keep the battery away from heat and flames Please use our designed charger 6 Stop using the machine if the battery is bulging 7 Switch off the machine when the buzzer alarm and use the machine after troubleshooting 8 Switch off the machine and remove the battery before checking and repairing the machine 9 Wear...

Страница 11: ...ch are caused by machine testing 2 When the wire is used up pull out the rest wire along with the wire coil Don t cut the wire directly or the machine will get stuck If the wire could not be pulled out check if the wire cut blade was clamped and revolve the jaw with diagonal pliers to pull out the wire ...

Отзывы: