INSTALLATION GUIDE FOR RX-4122
ENU STATUS : 1-0-1
Copyright - refer to title page
Page 29
Figure 15: 400MHz Screen
5.2.2 [COMMISSIONING]
A work flow of the commissioning process is shown on [Commissioning] Screen. Click the [Start] button, the
software will guide you through the commissioning step by step. For details, please refer to chapter 5.3.
Figure 16: [Commissioning] Screen
5.2.3 [FIRMWARE]
There are two functions on the [Firmware] bar: [upgrade] and [swap]. [Upgrade] is used to upgrade software,
and [Swap] is to replace the current firmware version with the previous one.
Follow the steps shown below figure to upgrade the firmware.
Click to set Freq Low and
High, DL/UL Gain,
Enable/disable RF switch.
DL Freq Low
and High of
sub-bands
RF parameters
of sub-bands
Sub-bands
switch status