ID-Mobile Global Guide
230
Window comparator
Symbol
Inputs
Input
Type
Range[DIM]
Function
Input
A
Any
Compared value
Input HIGH
A
Same as 'Input'
Upper window limit
Input LOW
A
Same as 'Input'
Lower window limit
Outputs
Output
Type
Range[DIM]
Function
Output
B
N/A
Comparator output
Description
The block output is switched on whenever the input value is in the range defined by Lo and Hi
levels.