ID-Mobile Global Guide
228
1. If you want the ON level to be a constant, write the constant into this box. Otherwise
go back to the sheet, create an input on it and connect the sheet input to the block
input by dragging a wire.
2. If you want the OFF level to be a constant, write the constant into this box. Otherwise
go back to the sheet, create an input on it and connect the sheet input to the block
input by dragging a wire.
3. Rename the output.
Note:
Press the button (4) if you need to delete the currently configured source from the
box.
Note:
The inputs are assigned to their sources in the sheet by
dragging a wire
from the
input to the source.
Comparator with delay
Symbol
Inputs
Input
Type
Range[DIM]
Function
Input 1
A
Any
Compared value
Input 2
A
Same as
'Input 1'
Comparation level
Delay
A
0.0..3000.0 [s]
Comparation delay
Outputs
Output
Type
Range[DIM]
Function
Output
B
N/A
Comparator output
Description
The block works as an analog switch. It compares the input value with the comparation level.
The output will switch on if the input is equal or higher than the comparation level for time
longer than the delay.