Setpoint group
Load sharing
Related FW
3.0.0
Range [units]
0,0 .. 100,0 [%]
Default value
50,0
Step
0,1
Comm object
10099
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
See
Load sharing block diagram (page 151)
- the setpoint value is used instead of Engine Values: Speed
Request in loadsharing state, if Binary input Back Up Speed is active and LAI: Requested RPM reading via
analog input is out of range (sensor fail is detected).
Back Up Speed
Setpoint group
Load sharing
Related FW
3.0.0
Range [units]
0 .. 600 [s]
Default value
60
Step
1
Comm object
10102
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Engine clutch start protection. Start fail alarm is activated, if engine running condition is not detected during
MaxClStrPer delay time after Binary output Clutch Connect is closed.
MaxClStrtPer
Содержание InteliDrive DCU Marine
Страница 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Страница 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Страница 104: ...InteliDrive DCU Marine 3 0 0 Global Guide 104 8 Appendix 8 1 Controller objects 105 6 back to Table of contents ...
Страница 242: ...InteliDrive DCU Marine 3 0 0 Global Guide 242 Binary output to J1939 configuration Source Value 8 1 5 Analog Inputs ...
Страница 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Страница 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Страница 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...