InteliDrive DCU Marine - 3.0.0 Global Guide
142
Setpoint group
Engine protect
Related FW
3.0.0
Range [units]
8,0 .. Batt >V [V]
Default value
8,0
Step
0,1
Comm object
8387
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Warning level for low battery voltage.
Batt < V
Setpoint group
Engine protect
Related FW
3.0.0
Range [units]
0 .. 600 [s]
Default value
10
Step
1
Comm object
8383
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Delay for battery voltage alarms.
Batt Volt Del
Setpoint group
Engine protect
Related FW
3.0.0
Range [units]
0,0 .. 100,0 [%]
Default value
20,0
Step
0,1
Comm object
9950
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Engine overload protection limit. See
Requested RPM, Overload protection (PRP only) (page 27)
OverloadSpLim
Содержание InteliDrive DCU Marine
Страница 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Страница 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Страница 104: ...InteliDrive DCU Marine 3 0 0 Global Guide 104 8 Appendix 8 1 Controller objects 105 6 back to Table of contents ...
Страница 242: ...InteliDrive DCU Marine 3 0 0 Global Guide 242 Binary output to J1939 configuration Source Value 8 1 5 Analog Inputs ...
Страница 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Страница 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Страница 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...