ADJUSTMENTS
AND
TESTING
SIMPLA 50B-BT
SIMPLA 55BT
SIMPLA 65BT
SIMPLA 50BST
Doc. 10021896
Issued 09/2010
Ver. AB
Page
5 of 16
Water System Testing
1.
Check the
solution filter
just underneath the tank cap is
clean and functioning.
2.
Check the cleanliness and seal of the
solution filter
(in the
rear part of the machine, at frame level).
3.
Completely fill the solution tank with water.
4.
Check the seal of the tubes, the
solenoid valve
, and the
water tap
adjustment.
5.
Check the solution pours onto the floor in a continuous
manner when the tap is open.
Adjusting the brakes
1.
Fix the brake cable to the frame, tightening the
sheath