13
MACHINE PREPARATION
To charge the lead acid batteries proceed as follows:
1.
Engage the parking brake.
2.
Check that the machine's master switch is in the "0" position.
3.
Lower the brush head by means of the pedal on the back of the machine
4.
Lower the squeegee by means of the lever on the back of the machine.
5.
Check the recovery tank is empty, otherwise empty it (see the appropriate chapter).
6.
release the hinges (1) on the handlebars
7.
Rotate the tank as far as it will go, using the side handle (2)
8.
Lift the battery charger socket guard (3) on the back of the machine.
9.
Plug the battery charger cable into the electrical system of the machine.
10.
Plug the power supply cable of the charger into the mains socket.
When replacing the battery, be sure to use batteries suitable for the battery charger installed.
ATTENTION: the machine is equipped with an automatic system that
disconnects the power supply from the electrical system while the batteries are
being recharged
ATTENTION: in order not to cause permanent damage to the batteries it is
essential to avoid their complete discharge: arrange the recharge within a few
minutes of the switching on of the flashing "discharged batteries" signal
ATTENTION: never leave the batteries completely discharged, even if the
machine is not being used
ATTENTION: for the daily recharging of the batteries, you must fully respect
the indications provided by the manufacturer or retailer. All installation and
maintenance operations must be carried out by expert personnel, trained at the
COMAC assistance centre
WARNING Make sure that the battery charger green LED is on before using
the machine again
ATTENTION: danger of gas exhalation and leakage of corrosive liquids
ATTENTION: danger of fire: do not go near with free flames
3
2
1