26
PREPARATION OF MACHINE
The solution tank can be filled with water in three different ways:
1.
By unscrewing the filler cap (01) and filling it using a rubber tube or bucket.
ATTENTION: Check that the filter (02) under the filler cap (01) is positioned
correctly; this is to prevent impurities and dirt causing a malfunction in the
machine's water system.
2.
By using the rubber cap (03), which supports the water hose on its own, be sure to unscrew
the cap (01) to allow the proper vent of air.
3.
By using the optional system (05) for automatically topping up with clean water, which has a
float for controlling the overflow, be sure to unscrew the cap (01) to allow the proper vent of
air.
ATTENTION: Before inserting the female insert into the male insert (05) in the
rapid top-up kit, be sure to remove the cap (04).
Fill with clean water, at a temperature not higher than 50
°
C and not lower than 10°C . The
amount inside the tank can be seen by means of the level tube (04) on the front left of the seat.
24. DETERGENT SOLUTION (VERSION WITHOUT CDS)
After filling the solution tank with clean water add the liquid detergent to the tank in the
concentration and manner indicated on the detergent manufacturer's label. To prevent the
formation of an excessive amount of foam that could damage the vacuum motor, use the minimum
percentage of detergent required.
ATTENTION: Always use detergents whose manufacturer's label indicates
their suitability for scrubbing machines. Do not use acid or alkaline products
or solvents without this indication.
ATTENTION: protective gloves should always be worn before handling
detergents or acidic or alkaline solutions, to avoid serious injury to the hands.
ATTENTION: always use low-foam detergent. To avoid the production of foam,
put a minimum quantity of anti-foam liquid in the recovery tank before starting
to clean. Do not use pure acids.
25. FILLING THE DETERGENT CANISTER (VERSION WITH CDS)
After filling the solution tank with clean water, proceed as follows:
1.
Open the hatch (01) on the front of the steering column.