PREPARING TO WORK
Before beginning to work, with the versions without CDS, it is necessary to:
1.
Make sure the recovery tank is empty, otherwise empty it completely (read “
”).
2.
Verify that the quantity of detergent solution in the solution tank is suitable for the type of work you
wish to carry out, otherwise fill the solution tank (see the paragraph “
”). View the level tube (1) in the rear of the machine (
Fig. 1
).
3.
Make sure that the squeegee rubber blades are in good working condition. If not, carry out
”).
4.
Check the brush is in good working condition. If it isn't, replace it (see “INSTALLING THE BRUSH”).
5.
For B versions, make sure the device is switched off. If it isn't, press the main switch (2) on the back
of the device (
Fig. 2
).
N.B.
: in B versions, the main switch (2) is in the idle position when the LED inside it is OFF and
the activation symbol is not visible.
6.
For the BT - BTS - BTO versions, make sure the device is switched off. If it isn't, set the main switch
(3) to “0” by turning the key (4) a quarter turn to the left (
Fig. 3
). Remove the key from the instrument
panel.
7.
Grip the handle (5) on the left side of the recovery tank (
Fig. 4
) and turn the tank as far as it will go,
until it reaches the maintenance position (
Fig. 5
).
8.
Connect the battery connector (7) to the main system connector (6) (
Fig. 6
).
WARNING
: This process must be carried out by qualified personnel.
9.
Grip the handle (5) on the left side of the recovery tank (
Fig. 7
).
10.
Turn the recovery tank as far as it will go, to the work position (
Fig. 8
).
11.
For the BT - BTS - BTO versions, make sure the electronic brake is engaged. If it isn't, turn the lever
(8) in the direction indicated by the arrow. The traction gearmotor is located on the left side of the
device (
Fig. 9
).
12.
Make sure the water tap is fully open; the water adjustment knob (9) should be completely down
(
Fig. 10
).
13.
Check that the solution tank discharge cap (10) is closed. If it isn't, open it (
Fig. 11
).
Before beginning to work, with the versions with the CDS system, it is necessary to:
1.
Make sure the recovery tank is empty, otherwise empty it completely (read “
2.
Verify that the amount of water present in the solution tank is sufficient for the type of work you wish
to carry out, otherwise fill the solution tank (see the paragraph titled “
”). View the level tube (1) in the rear of the machine (
Fig. 1
).
3.
Make sure that the amount of detergent in the canister inside the solution tank is sufficient for the type
of work you want to carry out, otherwise fill it up with detergent (read “
4.
Make sure that the squeegee rubber blades are in good working condition. If not, carry out
”).
5.
Check the brush is in good working condition. If it isn't, replace it (see “INSTALLING THE BRUSH”).
6.
For BT versions, make sure the device is switched off. If it isn't, bring the main switch (2) to the
“0” position by making a quarter turn to the left with the key (3) (
Fig. 2
). Remove the key from the
instrument panel.
1
1
4
2
3
2
3
OFF
6
7
6
5
4
5
5
8
7
9
8
10
9
11
10
7.
Grip the handle (4) on the left side of the recovery tank (
Fig. 3
) and turn the tank as far as it will go,
until it reaches the maintenance position (
Fig. 4
).
8.
Connect the battery connector (6) to the main system connector (5) (
Fig. 5
).
WARNING
: This process must be carried out by qualified personnel.
9.
Grip the handle (4) on the side of the recovery tank (
Fig. 6
).
10.
Turn the recovery tank as far as it will go, to the work position (
Fig. 7
).
11.
For BT versions, make sure the electronic brake is engaged. If it isn't, turn the lever (7) in the direction
of the arrow. The traction gearmotor is located on the left side of the device (
Fig. 8
).
12.
Make sure the water tap is fully open: the water adjustment knob (8) should be completely down
(
Fig. 9
).
13.
For the BT versions, bring the main switch (2) to its “I” position by turning the key (3) a quarter turn
to the right
Fig. 10)
).
14.
When the work screen appears on the control display, press the water flow adjustment button (9)
(
Fig. 11
).
N.B.
: Set the amount of water present in the dosing system to maximum by pressing the button
(10) until the “WATER LEVEL ADJUSTMENT” symbol is completely filled (
Fig. 12
).
15.
After adjusting the amount of water in the dosing circuit, press the button (10) for adjusting the
detergent percentage supplied by the dosing system (
Fig. 13
).
NOTE
: Set the percentage of detergent present in the dosing system to the maximum value by
pressing the button (10) until the “DETERGENT
PERCENTAGE ADJUSTMENT” symbol
is
completely filled
(Fig. 14
).
16.
Check that the potentiometer knob (11) is set to minimum, otherwise turn it completely counter-
clockwise (
Fig. 15
).
N.B.
: the device will not start to move (either forward or backward) if the potentiometer adjustment
knob (11) is set to minimum.
17.
Lower the brush head unit by pressing the brush head control pedal (12) on the back of the appliance
(
Fig. 16
).
18.
Lower the squeegee unit using the lever (13) on the back of the appliance (
Fig. 17
).
19.
When the dead man's lever (14) is activated (
Fig. 18
), the brush head gearmotor and the vacuum
motor will enter into function. At the same time, the solenoid valve and dosing system will begin
supplying the detergent solution to the brush.
20.
Wait a few moments, keeping the accelerator pedal gently depressed (normally 40 - 60 seconds) to
allow the system to engage.
1
1
3
2
2
3
4
4
5
6
5
5
6
7
8
7
9
8
3
9
2
10
11
12
10
13
14
11
15
12
16
13
17
14
18
22