P
P
a
a
g
g
e
e
1
1
0
0
o
o
f
f
4
4
0
0
I
I
N
N
S
S
T
T
R
R
U
U
C
C
T
T
I
I
O
O
N
N
M
M
A
A
N
N
U
U
A
A
L
L
A
A
P
P
F
F
-
-
5
5
0
0
6
6
0
0
M
M
A
A
G
G
N
N
E
E
T
T
I
I
C
C
F
F
I
I
E
E
L
L
D
D
G
G
E
E
N
N
E
E
R
R
A
A
T
T
O
O
R
R
S
S
E
E
C
C
T
T
I
I
O
O
N
N
3
3
-
-
P
P
R
R
O
O
D
D
U
U
C
C
T
T
I
I
N
N
F
F
O
O
R
R
M
M
A
A
T
T
I
I
O
O
N
N
1
1
9
9
1
1
2
2
1
1
E
E
L
L
T
T
O
O
R
R
O
O
R
R
O
O
A
A
D
D
●
●
S
S
I
I
L
L
V
V
E
E
R
R
A
A
D
D
O
O
,
,
C
C
A
A
L
L
I
I
F
F
O
O
R
R
N
N
I
I
A
A
9
9
2
2
6
6
7
7
6
6
●
●
(
(
9
9
4
4
9
9
)
)
4
4
5
5
9
9
-
-
9
9
6
6
0
0
0
0
●
●
c
c
o
o
m
m
-
-
p
p
o
o
w
w
e
e
r
r
.
.
c
c
o
o
m
m
Rev091918
3
3
.
.
4
4
P
P
r
r
o
o
d
d
u
u
c
c
t
t
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
ON
OFF
TXD RXD
REMOTE ON
PAUSE
Waveform
POWER
POWER
REMOTE
REMOTE
MONITOR
MONITOR
INSTRUMENT STATUS
INSTRUMENT STATUS
OUTPUT
OUTPUT
OVER TEMPERATURE
OVER TEMPERATURE
INTERLOCK
INTERLOCK
OVER CURRENT
OVER CURRENT
I
50 Hz
60 Hz
ACTIVE
ACTIVE
APF-5060
MAGNETIC FIELD GENERATOR
1 2
4
7
3
6
8 9
10
5
11
12
12
13
14
13
14
F
F
i
i
g
g
u
u
r
r
e
e
1
1
–
–
P
P
r
r
o
o
d
d
u
u
c
c
t
t
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
–
–
A
A
P
P
F
F
-
-
5
5
0
0
6
6
0
0
(
(
F
F
r
r
o
o
n
n
t
t
)
)
LCD Display
1
Used in conjunction with control keypad to operate generator from the front panel.
Safety Interlock Port
2
This is a safety interlock port. Refer to section 5.2 for details.
Control Keypad
3
For locally controlling the generator. Refer to section 6.6.1 for details.
OUTPUT ACTIVE LED Indicator
4
When illuminated, indicates that the output of the generator is active.
Instrument Status LED Indicators
5
These three LED indicators, when illuminated, provide indications in case of over-temperature, over-current and/or the safety
interlock circuit is open.
Front Panel Power Switch
6
Used to turn on/off system power when the rear panel power switch is in the ‘ON’ position.
REMOTE Fiber Optic Port and LED Indicator
7
CURRENTLY NOT SUPPORTED.
50 Hz LED Indicator
8
When illuminated, indicates that the output frequency of the generator is set to 50 Hz.
WAVEFORM Port
9
This port may be connected to an oscilloscope to verify the output frequency of the generator. The waveform present at this
output port is a 2.7Vrms square wave. This port is equipped with a female BNC-type connector.
60 Hz LED Indicator
10
When illuminated, indicates that the output frequency of the generator is set to 60 Hz.
Generator Output Terminals
11
The Generator Output Terminals are equipped with Superior Electric Sockets for connection to the inductive loop coil.
Front Panel Handles
12
These handles are typically used for rack-mount installation; for sliding the generator in and out of the rack.
Bottom-side Rubber Feet (front)
13
For rack-mount installation, these feet may be removed by removing the two screws (per foot) which attach the feet to the
chassis. The screws can then be removed from each foot and screwed back into their respective holes to re-secure the bottom
cover.
Top-side Rubber Feet (front)
14
For rack-mount installation, these feet may be removed by removing the two screws (per foot) which attach the feet to the
chassis. The screws can then be removed from each foot and screwed back into their respective holes to re-secure the top
cover.