Colzer PD123A Скачать руководство пользователя страница 8

4

HUMIDITY Button:

Press the HUMIDITY button repeatedly to adjust the set-point of humidity level

between 30%-80% (in 5% increments) during normal DEHUMIDIFY (DH) mode. The digital number
on the display will flash when changes are being made.

NOTE:

The HUMIDITY button will be disabled in the DRY-CLOTHES (DRY) mode.

SPEED Button:

Press the SPEED button to set the fan speed to FAST or SLOW in the normal

DEHUMIDIFY (DH) mode.

NOTE:

The SPEED button will be disabled in the DRY-CLOTHES (DRY) mode.

TIMER Button:

Use this TIMER button to set

an AOTU-ON or AUTO-OFF timer, between 1-24 hrs.

When timer function is enabled, the system will countdown the time remaining and you can check
the time remaining by pressing the TIMER button once.

LIGHTING Button:

Press the LIGHTING button to

send the display to sleep status where

the digital

display and the backlight of the buttons other than the POWER button and the LIGHTING button will
go off and these buttons will be disabled, while the dehumidifier maintains running status. The
indicator light above the LIGHTING button will light up in this case. Press the LIGHTING button again
to restore the backlight and functions of these buttons.

NOTE:

Press and hold the SPEED button for 3-5 seconds, the LCD will show the room temperature

readout in Fahrenheit. 5 seconds later, the LCD will turn back to display the room humidity readout.

2) Understand the LCD Display

The BIG FONT Digital Number

is humidity reading. If no operations on the control panel, the

number is the humidity percentage readout of the inlet air the dehumidifier detects which is similar
to the room humidity level. When you are pressing the HUMIDITY button to set the target humidity
percentage value, the digital number will turn to display the setting value and flash.

FULL:

The

Full

icon will light up when the bucket is full of water, as a reminder to empty the water

bucket. Empty the bucket and re-install the bucket properly to resume regular functioning.

FAST:

The

FAST

icon will light up when the FAN speed was set to high.

SLOW:

The

SLOW

icon will light up when the FAN speed was set to low.

DRY:

The

DRY

icon will light up when the DRY-CLOTHES mode has been selected.

Содержание PD123A

Страница 1: ...COLZER Dehumidifier User Manual Model No PD123A PD223A Please read this User Manual before operating and keep safe for future reference...

Страница 2: ...event any internal damage it is very important to keep refrigeration products like this dehumidifier upright throughout their journey Please leave it standing upright and outside the box for 24 HOURS...

Страница 3: ...on operation instructions troubleshooting maintenance tips and warranty information to ensure the reliability and longevity of your dehumidifier We also kindly ask you to take a few minutes to registe...

Страница 4: ...Mode 6 1 DH DEHUMIDIFY Mode 6 2 DRY Laundry Dry Mode 7 5 Timer Setting 7 6 Drain Collected Water 8 1 Emptying the Water Bucket 8 2 Continuous Drain by Gravity 9 7 Smart Functions 10 1 Auto Shut Off 1...

Страница 5: ...r other water containers on top of the dehumidifier 11 Do not climb on or sit on the dehumidifier 12 Do not operate or turn off the dehumidifier by plugging in or unplugging the dehumidifier Use the c...

Страница 6: ...2 PARTS IDENTIFICATION NOTE DO NOT OBSTRUCT THE AIR INLET AND OR OUTLET...

Страница 7: ...rol Panel The top control panel features a digital display and 6 buttons 1 Understand the Control Buttons POWER Button Press to turn the dehumidifier ON or OFF Mode Button Press to switch the working...

Страница 8: ...intains running status The indicator light above the LIGHTING button will light up in this case Press the LIGHTING button again to restore the backlight and functions of these buttons NOTE Press and h...

Страница 9: ...closed Maintain a minimum clearance of 20 cm 7 9 inches on the sides and back of the dehumidifier and 40 cm 16 inches on the top of the dehumidifier to allow for proper air circulation To use the deh...

Страница 10: ...omatically restart when the room humidity raises up to 53 NOTE When the set humidity level is not at least 3 lower than the room humidity level the dehumidifier won t start and DH icon will flash When...

Страница 11: ...ping into the dehumidifier Close the windows and doors Run the dehumidifier in the DRY CLOTHES mode 5 Timer Setting The TIMER function enables you to either Delay AUTO ON or Delay AUTO OFF the dehumid...

Страница 12: ...ot So The TIMER will ONLY function one time instead of cycling the dehumidifier on or off indefinitely Before entering the AUTO ON TIMER setting make sure power is being supplied to the dehumidifier 6...

Страница 13: ...hose NOTE You can use any other hoses with inner diameter of 5 8 0 63 inches instead To Achieve Continuous Drain by Gravity Remove the plastic cover from the continuous drain outlet Remove the water...

Страница 14: ...tart operation following a complete cycle until after 3 minutes The operation will automatically start after 3 minutes For example when the dehumidifier has been turned on immediately after being turn...

Страница 15: ...d the correct angle to take the handle out more easily Find the clasps on the bucket lid press bucket inward to release the lid from the clasps Partially fill the reservoir with clean water and add a...

Страница 16: ...or half a day and then wait 1 day before emptying the reservoir Clean the main dehumidifier water reservoir and air filter Ensure the whole dehumidifier is clean and dry Wrap the cord and bundle it Co...

Страница 17: ...360W Wattage 80 F 60 185W Wattage 65 F 60 260W Airflow Rate 112 CFM 190 CMH 112 CFM 190 CMH Refrigerant R134a 5 6 oz R134a 8 1 oz Protection Type of Preventing Electric Shock I I IP Level IP21 IP21 He...

Страница 18: ...the system auto reset to default settings 3 Trouble Shooting The below chart will help you solve common problems that may occur If the problem you come across can not be fixed after troubleshooting or...

Страница 19: ...that give off vapor in the room The room temperature is low Heat up the room The dehumidifier size is too small for the room Increase the quantity of dehumidifiers Or change a higher capacity dehumid...

Страница 20: ...the proven defective product through repair or replacement of any defective part and necessary labor so that it conforms to its original specifications A replacement product may be provided instead o...

Отзывы: