background image

3

COLUMBIA  SPECIFICATIONS  

1622 Browning   Irvine, CA   92606-4809   Phone: 949.474.0777   Toll Free: 800.626.2117   Fax: 949.474.1191   

www.columbiasinks.com

   email: info@

columbiasinks.com

©2019 Columbia Products

HANDS-FREE FLOOR MOUNTED WASH STATIONS

Valve Repair Instructions

Note: Valves are designed to be repaired without having to be disconnected from mount or plumbing.
1. Turn off water source. Do not remove valve from sink.
2.  Remove pedal assembly using a 15/16” open end wrench or socket wrench. As shown in 

illustration A.

3.  Using a 1” deep socket wrench remove insert assembly parts as show in illustration B. 
4.  Replace with new repair kit as shown on illustration C.
5. Reinstall pedal assembly and turn water source on.

Trouble Shooting Guide

Problem

Possible Cause

To Diagnose

Remedy

Water drips from spout 

or valve stem assembly.

Flat washer on the 

stem/plunger is worn.

To determine if the leak source is from the hot or cold side shut 

cold water source off. See if water still leaks from the spout. If 

leak continues then repair hot side if not repair cold side.

We recommend installing valve repair 

kit.

Water leaks from the 

front of the valve.

O-Rings on the 

plunger are worn out.

Visually determine whether the cold or hot side is leaking.

We recommend replacing threaded 

insert, plunger assembly & spring. 

See illustrations below.

Illustration A

Illustration B

Illustration C