Ink Supply System Maintenance
•
Check for leakage between joint & ink tank and joint & valve settings.
•
Check for damages on ink tubes.
•
Check Ink impurities in the ink tanks as this will affect the ink supplying.
Water Chiller Operating Instructions
•
It is forbidden to put the water chiller under the temperature environment 0°C, otherwise the circulating
water would ice, which generates frost damage to the equipment! (If the water chiller must be preserved
in below 0°C environment, please take the following measures:
o
Please be sure to drain the water 0ff in the water chiller immediately after it is switched off and
then fill it full with water before next operation;
o
Please add antifreeze appropriately in the circulating water in order to reduce the freezing point.
Note:
Add antifreeze according to the requirements of the cooling equipment.)
•
It is forbidden to tilt the water chiller or to carry or place it inverted. It must not be switched on again after
normal handling until the machine has been standing still for 2 hours!
•
Make sure that the air is removed from the water pump before the water chiller is switched on. Strictly
prohibit empty running the water chiller!
•
Don’t plug or unplug the joints when the water chiller is running.
•
The water chiller’s normal operating
temperature range is 10°C to 35°C. If the temperature is beyond the
range, please contact the manufacturer.
•
Make sure that the water chiller is operated in a smoothly ventilated environment and it is barrier free in
0.5 meter on both sides of the air inlet and air outlet.
•
Make sure that the water tank is filled with water before the machine is switched on, then fill the tank
again after one minute’s running to avoid the low water level alarm leads to abnormal operation of the
water chiller.
•
Distilled water is the best to be used as circulating water, then is high quality pure water. Don
’
t use tap
water or other water which contains acid, alkali, corrosive or mineral substance.
•
Circulating water temperature is set according to the standard that no dew appears on the surface of the
cooled parts. It is easy to damage the equipment damage if there’s dew on the surface of the parts. Please
set the temperature value according to the environmental temperature and relative humidity.
•
The water chiller must be placed in a horizontal plane and fixed before it works.
•
The length of the pipe to connect the water chiller and cooled equipment should not be longer than 8m
(4m one path). If not, the pipe resistance would increase and the flow rate would decrease that will result
in abnormal operation or damage of the water chiller and cooled equipment.
•
Check whether the water level is normal, the pipe is blocked and pipeline valve is normally opened before
the machine is switched on.
•
Clean the condenser fins and fan blades every 7 days (cleaning method: open the air inlet and then
blowout the dust of condenser with air pressure gun).
•
Replace the circulating water every 1 to 2 months and clean the water tank, water pipe and joints.