SubliXpress
When you press the
Next
button, we redirect to the software calibration screen, as shown in the
below images:
Fig 24: Displaying the Bidirectional Check in Calibration Wizard
Let’s discuss each test and their result one by one in upcoming section. Mechanical check
s are
performed by Service Engineer; thus, these checks are not discussed in the user manual.
Horizontal Calibration
Horizontal Calibration checks the bi-directional, left, and right alignment and corrects it by adding or
subtracting the correction value from the default set value. It has to be performed for each print mode,
whichever is required. Let’s discuss each type of horizontal test one by one.
Bi-direction Calibration
Bi-directional calibration is performed to achieve dot placement accuracy betwee
n the “Left to Right”
and “Right to Left” print sweeps. If the bi
-direction offset value is correct, the Left to Right test print
would align accurately with the Right to Left test print at
“0”
position. In case of error in the Bi-
Direction offset, the Left to Right and Right to Left print would align at some other point on the scale.