Metro (Konica Head)
When you press the
Next
button, we redirect to the software calibration screen, as shown in the below
images:
Fig 47: Displaying the Printer Calibration Options
Horizontal Calibration
Horizontal Calibration checks the bi-directional, left, and right alignment and corrects it by adding or
subtracting the correction value from the default set value. It has to be performed for each print mode,
whichever is required. Let’s discuss each type of horizontal test one by one.
Bi-direction Calibration
Bi-directional calibration is performed to achi
eve dot placement accuracy between the “Left to Right” and
“Right to Left” print sweeps. If the bi
-direction offset value is correct, the Left to Right test print would
align accurately with the Right to Left test print at
“0”
position. In case of error in the Bi-Direction offset,
the Left to Right and Right to Left print would align at some other point on the scale.