background image

INTRODUCTION

Color Kinetics® iW PDS-60 is a compact power/data supply for 

indoor installations. iW PDS-60 provides power and data to Color 

Kinetics IntelliWhite Series fixtures.
This guide contains important information on installing and using 

your new iW PDS-60. Please read it carefully and save it for future 

reference. There are few rules, but those that exist are there for your 

safety. 

Included in this box:

•  Power/data supply
• US IEC power cable
• Terminator
• 2 3-Pin Terminal Blocks
• Installation Guide
• Warranty and Registration cards

A

dditional items needed:

•  Mounting hardware-- 4 flat head screws M3 or #6

Scope of this User Guide

The goal of this user guide is to explain in easily understandable  

language the necessary steps to install iW PDS-60 with iW Zone control 

and assure peak performance. Its intended use is for reference only, by 

persons who are fully qualified. This document should never be consid-

ered a substitute for any provisions of a regulation or state and/or local 

code.

Identification and Warnings of Safety Hazards

In accordance with ANSI Z535.4-2002, the following system identi-

fies the severity of the hazards associated with the products:

DANGER

”  Imminently hazardous situation which, if not avoided, will 

result in death or serious injury.

WARNING

” Potentially hazardous situation that, if not avoided, could 

result in death or serious injury.

CAUTION

”  Potentially hazardous situation that, if not avoided, may 

result in minor or moderate injury or property damage.

WARNING

: Ensure that power is disconnected before installing, wiring, 

or servicing iW PDS-60. Failure to adhere to these instructions can 

result in death or serious injury.

WARNING

: iW PDS-60 must be installed by a qualified professional in 

accordance with NEC and relevant local codes. Failure to comply can 

result in death, serious injury, or property damage.

WARNING

: Do not attempt to install or use iW PDS-60 until you read 

and understand the installation instructions and safety labels.  Failure 

to adhere to these instructions could result in serious injury or property 

damage.

WARNING

: Do not use iW PDS-60 if power cables are damaged.  

Doing so can result in death, serious injury, and property damage.

WARNING

: This is a class A product. In a domestic environment this 

product may cause radio interference in which case the user may be 

required to take adequate measures.

CAUTION

: Ensure that iW PDS-60 is securely attached, properly 

mounted, and free of excessive vibration. Failure to do so will result in 

property damage and void the warranty.

CAUTION

: Do not hot swap. Ensure the power supply is off before 

connecting or disconnecting fixtures. Hot swapping will result in 

property damage and void the warranty.  

CAUTION

: Do not modify or alter iW PDS-60. Doing so will void the 

warranty.

NOTE

:

 

The instructions and precautions set forth in this user guide 

are not necessarily all-inclusive, all conceivable, or relevant to all 

applications as Color Kinetics cannot anticipate all conceivable or 

unique situations.

Owner/User Responsibilities

It is the responsibility of the contractor, installer, purchaser, owner, and 

user to install, maintain, and operate iW PDS-60 in such a manner as 

to comply with all state and local laws, ordinances, regulations, and 

the American National Standard Institute Safety Code.

NOTE

:

 iW PDS-60 is shipped with a US IEC power cable. For interna-

tional customers, use a country-specific IEC cable meeting the follow-

ing specifications: 3-conductor, 18AWG (1.00mm2), HAR rating for 

Europe, and JET rating for Japan.

INSTALLING iW PDS-60

iW PDS-60 shall be installed by a qualified electrician in accordance 

with NEC and relevant local codes for power supplies.

Installation Considerations

• iW PDS-60 uses Color Kinetics iW Scene Controller to control Color 

Kinetics IntelliWhite dimmable, color temperature adjustable fixtures 

by zones. A zone is a grouping of lights attached to an iW power/

data supply which has been set to a specified zone designation. 

The zone designation of the iW power/data supply defines the 

zone in which the lights reside. Using iW Scene Controller, you can 

set the brightness level and color temperature, from cool to warm, 

for all lights within specified zones. 

Zones are created by designating each iW PDS-60 as a specific 

alphanumeric zone, 1-9 or A-F. All fixtures attached to that iW 

PDS-60 reside within the designated zone. For example, in an 

installation with two iW PDS-60s where the first power/data supply 

is set to Zone 1 and the second is set to Zone 2, the lights attached 

to the first are in Zone 1 and the lights attached to the second iW 

PDS-60 are in Zone 2.
For installations where all lights are controlled in unison, set each 

power/data supply in the installation to the same zone designator. 

For installations where groups of lights are controlled separately, set 

unique zone designators for each power/data supply. 

• Location of iW PDS-60 in relationship to lights: Refer to the user 

guide for your IntelliWhite fixture to determine the maximum 

distance from the fixture to install iW PDS-60.  

NOTE

: Adhere to all state and local wiring codes when making the 

leader connections.

•  Maximum number of fixtures per iW PDS-60: Refer to the user guide 

for your IntelliWhite fixtures to determine the maximum number of 

fixtures per iW PDS-60.

STEPS TO A SUCCESSFUL INSTALLATION

1. Install iW PDS-60.
2. Connect iW Scene Controller.
3. Connect the lights to iW PDS-60.
4. Connect power to iW PDS-60.
5. Set the zone(s) for iW PDS-60s.

Step 1: Install iW PDS-60 

•  Select the location to mount the housing, keeping iW PDS-60 within 

the maximum distance specified for your fixture. Refer to your fixture 

user guide for the cable run information.

•  Mount the housing to a flat surface using four M3 or #6 flat head 

screws suitable for the mounting surface. Mounting slots are located 

on each end of the housing. See Fig. 1.

   

NOTE

Do not overtighten the mounting screws.

Step 2: Connect iW Scene Controller 

To control Color Kinetics IntelliWhite fixtures with iW PDS-60,  

iW Scene Controller is required. Depending on the installation 

parameters and configuration, iW Scene Controller can control one 

or multiple iW PDS-60s. Refer to the iW Scene Controller Installation 

Guide for complete instructions.

• Install iW Scene Controller in a single gang wall box within  

50 feet (15m) of the iW PDS-60. 

• Pull the provided iW Scene Controller leader cable to the  

iW PDS-60.

•  Plug the 4-pin connector at the end of the iW Scene Controller 

Leader Cable into the connector located on the back of the 

controller. Plug the other end into the Controller connector located 

on the front panel of the iW PDS-60. See Fig. 2.

NOTE

: iW Scene Controller provides data to, and receives power 

from, iW PDS-60; therefore, no external power supply is needed for 

iW Scene Controller.

i

W  PDS-60

I N S T A L L A T I O N

 

G U I D E

Color Kinetics Incorporated
10 Milk Street, Suite 1100
Boston, MA 02108
Tel 888 Full RGB
Tel 617 423 9999
Fax 617 423 9998
[email protected]
www.colorkinetics.com

ITEM# 509-000002-00

FOR USE UNDER U.S. PATENTS 6,016,038, 6,150,774, 6,340,868, 6,788,011, 

AND 6,806,659

OTHER PATENTS PENDING

©2005 Color Kinetics Incorporated. All rights reserved. Chromacore, Chromasic, 

Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorCast, 

ColorPlay, ColorScape, Direct Light, iColor, iColor Cove, iPlayer, Optibin, QuickPlay, 

Sauce, the Sauce logo, and Smartjuice are registered trademarks and DIMand, 

IntelliWhite, Powercore, and Video With Light are trademarks of Color Kinetics 

Incorporated.
PUB-000132-00 Rev 00

CAUTION

: iW PDS-60 must be installed in a location that allows air to 

move freely. Packing insulation around the housing or mounting in a 

sealed location that raises ambient temperature above 122˚F (50˚C)  

will result in property damage and void the warranty.

8.31”

(21.2 cm)

2.25”

(5.7 cm)

Fig. 1

ZONE NET IN

ZONE NET OUT

OUT 1

OUT 2

iW PDS-60

OUT 1

OUT 2

iW PDS-60

iW Scene

Controller

TERMINATOR

ZONE NET IN

ZONE NET OUT

CONTROLLER

CONTROLLER

DATA OUT

DATA IN

DATA IN

Fig. 2

Отзывы: