background image

INTRODUCTION

Welcome to a more colorful world brought to you by Color 

Kinetics. Chromacore®, our patented core technology, generates 

and controls millions of colors and a variety of lighting effects 

using a microprocessor to control LEDs. This User Guide contains 

important information about installing and operating your new 

ColorBlast® 6 fixture safely. 

Included In This Box

•  ColorBlast 6 with base

• Outdoor junction box gasket for standard US junction boxes

• Water-tight grommet assembly

• 2 8-32 screws for indoor standard US junction boxes with  

   3.5" center to center mounting holes

• 4 10-24 stainless steel screws for outdoor junction boxes

• Hex key wrench (3/32")

• User Guide

Additional Items Needed

•  4” 

Electrical junction box (rated for your application) with 3.5” 

center to center distance for mounting locations

•  24VDC Color Kinetics power/data supply 

PDS-150e (Item# 109-000008-01) or 

PDS-60 24V (Item# 109-000017-00/03)

•  Controller - Color Kinetics DMX Controller or DMX compatible

• Color Kinetics Zapi (Item# 103-000005-00, US/103-000005-01, EU) 

or Serial Addressing Software (SAS) with iPlayer 2 or  

Smart Jack 3

• Adjustable wrench

• Phillips head screw driver

Scope of This User Guide

The goal of this user guide is to explain in an easily understood lan-

guage the necessary steps to install ColorBlast 6 and assure peak 

performance. Its intended use is for reference only, by qualified profes-

sionals. This document should never be considered a substitute for any 

provisions of a regulation or state, local and/or national codes.

Identification and Warnings of Safety Hazards

In accordance with ANSI Z535.4 the following system of identifying 

the severity of the hazards associated with the products is used:

danger

”  Imminently hazardous situation which, if not avoided, 

will result in death or serious injury.

warning

” Potentially hazardous situation that, if not avoided, 

could result in death or serious injury.

caution

”  Potentially hazardous situation that, if not avoided, may 

result in minor or moderate injury or property damage.

danger

: Ensure that the main power supply is off before install-

ing or wiring ColorBlast 6 and the power/data supply.  Failure to 

adhere to these instructions will result in death or serious injury.

warning

: ColorBlast 6 and the power/data supply must be 

installed by a qualified professional in accordance with NEC and 

relevant local codes. Failure to comply can result in death, serious 

injury, or property damage.

warning

: Do not attempt to install or use ColorBlast 6 or the 

power/data supply until you read and understand the installation 

instructions and safety labels.  Failure to adhere to these instructions 

could result in serious injury or property damage.

caution

: ColorBlast 6 has no serviceable parts. Do not attempt to 

open the fixture. Doing so will result in property damage and void 

the warranty.

caution

: Do not modify, alter, or attempt to service ColorBlast 6. 

Doing so will void the warranty.

caution

: Do not use sharp tools near or on the fixture lens. Doing 

so will result in property damage and void the warranty.

caution

: Do not hot swap. Ensure the power supply is off before 

connecting or disconnecting fixtures. Hot swapping will result in 

property damage and void the warranty.

note

: The instructions and precautions set forth in this installation 

guide are not necessarily all-inclusive, all conceivable, or relevant to 

all applications as Color Kinetics cannot anticipate all conceivable 

or unique situations.

Owner/User Responsibilities

It is the responsibility of the contractor, installer, purchaser, owner 

and user to install, maintain, and operate ColorBlast 6 in such a 

manner as to comply with all state, local, and national laws, ordi-

nances, regulations, and the American National Standard Institute 

Safety Code.

PLANNING THE INSTALLATION

T

he nature of a ColorBlast 6 installation requires planning to ensure 

a timely, successful installation with minimal complications and 

down time. 

Planning Suggestions

When planning a ColorBlast 6 installation, Color Kinetics suggests 

doing the following:
•  Consult an Electrical Inspector to approve all wiring plans.
•  Refer to local and state codes for installation compliance.
•  Create a Mapping Grid. Use this grid to record serial numbers 

for easy reference and addressing.

•  Create a Layout Plan drawing, per Lighting Designer or Architect.
•  Employ Color Kinetics Application Engineering Services. 
•  Get detailed wiring diagrams and additional support from  

http://support.colorkinetics.com.

Installation Considerations

When creating your installation plan, consider the following:
•  Location of power/data supply in relationship to lights. 
  •  Maximum accumulated cable length for all ColorBlast 6 fixtures 

connected to a single PDS-150e is 400 feet. Maximum single 

cable run between PDS-150e and ColorBlast 6 is 150 feet.

  •  Maximum cable length for a ColorBlast 6 fixture connected 

to a PDS-60 24V is 150 feet. Therefore, PDS-60 24V must be 

located within 150 feet of the furthermost supported fixture. 

•  Location of fixture and method of mounting. ColorBlast 6 can be 

installed indoors or outdoors on a wall, ceiling, or floor. Junction 

boxes and mounting methods vary according to location. 

INSTALLING COLORBLAST 6

Steps to a Successful Installation

1. Record serial numbers and identify fixtures as you unpack them.
2. Install the power/data supplies.
3. Address the light fixtures.
4. Install ColorBlast 6 fixtures.
5. Make electrical connections.

Recording Serial Numbers

1. As you unpack the fixtures record the serial numbers.  

    Each ColorBlast 6 has a unique serial number programmed at 

    the time of manufacture.
2. Write the serial numbers onto a Mapping Grid or use a bar code 

scanner along with Color Kinetics Serial Addressing Software 

(SAS) to record each serial number. SAS and instructions are 

located at www.colorkinectics.com/support/downloads.

3. Using the Layout Plan, assign the fixture to a layout position in 

the installation.

4. Using a weatherproof label, identify the fixtures installation posi-

tion based on the Layout Plan. Place the identifying label in an 

inconspicuous location noting the order or placement in the instal-

lation. This step not only minimizes installation mistakes, but aids 

in post-installation light shows programming.

Installing the Power/Data Supply

Following the Layout Plan, install the power/data supplies 

according to state and local codes. Refer to the PDS-150e or 

PDS-60 24V Installation Guides for complete instructions.

warning

: Ensure that the power is off before wiring or connecting 

fixtures to the power/data supply. Failure to do so can results in 

serious injuries or death.  

caution

: Never lengthen the ColorBlast 6 cable. Doing so will 

result in property damage and void  the warranty.

Addressing the Lights

important

: Before you begin the installation, consider the scope of 

your lighting application and installation. Your ColorBlast 6 is set 

to light address one (1) at the factory. If your application requires 

other addresses, set the light addresses using one of the following 

addressing tools:

zapi

: Use Color Kinetics Zapi to set the DMX address for each 

fixture or set all fixtures to the same DMX address. Refer to the 

Zapi User Guide for step-by-step addressing instructions.

sas

 (

serial

 

addressing

 

software

)

: Use a PC with iPlayer 2, or a 

PC with Smart Jack 3 to address the fixtures. Download SAS and 

instructions from www.colorkinetics.com/support/downloads.

light

 

system

 

manager

 (

lsm

or

 

video

 

system

 

manager

 (

vsm

)

Use LSM or VSM software to discover and address all fixtures via 

Ethernet. For detailed information on using LSM or VSM, see the 

LSM or VSM User's Guides. 

note

: All of these tools can be used to address light fixtures either 

pre-installation or post-installation (to save time). 

note

: For applications using multiple, daisy-chained power supplies, 

you can address all lights in the chain by attaching Zapi to the first 

power supply in the series.  

Setting Individual Addresses

Using the Serial Number mode of Zapi 1.5 or SAS, address each 

fixture attached to a power supply or a series of connected power 

supplies individually. 
1.  With power disconnected, connect up to six ColorBlast 6 fixtures 

to the power/data supply.

2.  Attach the DMX interface (Zapi, iPlayer 2, or Smart Jack 3) to the 

DMX IN

 port on the power/data supply.

3.  Connect power to the power/data supply.

4. Use Zapi or SAS to set the light address for each serial number.

5.  Disconnect power and then disconnect the addressed  

ColorBlast 6 fixture(s).

6.  Repeat steps 1 through 5 for all remaining fixtures. 

7. After all fixtures are addressed, disconnect the DMX interface.

Setting the Same Address to Multiple Lights

Using Zapi 1.5, address all fixtures attached to a power supply or 

multiple, daisy-chained power supplies. 
1.  With power disconnected, connect up to six ColorBlast 6 fixtures 

to the power/data supply.

2.  Attach the Zapi to the 

DMX IN

 port on the power/data supply. 

3.  Connect power to the power/data supply.

4.  Use Zapi to set the light addresses. All ColorBlast 6 fixtures con-

nected to the power/data supply are addressed simultaneously.

note

: If you are using SAS, you must input each serial number 

(address) separately. 

5.  Disconnect the DMX interface.

Installing ColorBlast 6 Fixtures

This fixture must be installed by a qualified electrician in accor-

dance with NEC and relevant local codes for Class 2 power 

sources. 
ColorBlast 6 can be installed indoors or outdoors. When mounting 

on walls and ceilings, use an electrical junction box rated for your 

application. 

Through-Base Cable Assembly

For all installations where the cable must go through the canopy 

base, follow the directions below to prevent cable damage and to 

create a water-tight seal for outdoor installations. 
1. Screw the liquid-tight fitting into the canopy base. The O-ring 

must be seated against the canopy opening to ensure a water-

tight seal.

2. Insert the fixture cable through the dome nut. Loosen the dome 

nut if necessary. Pull the cable through the fitting. Leave enough 

cable above the fitting to ensure full fixture head rotation.

3. Tighten dome nut to seal the cable. After 24 hours, tighten the 

dome nut again to ensure proper sealing force and water-tight 

seal. (See Fig. 1.)

Color Kinetics Incorporated
10 Milk street, Suite 1100
Boston, MA 02108 USA
Tel 888 Full RGB
Tel 617 423 9999
Fax 617 423 9998
[email protected]
www.colorkinetics.com

ITEM#  116-000013-00 (White, Frosted)

 

116-000013-01 (Black, Frosted)

 

116-000013-02 (White, Clear)

 

116-000013-03 (Black, Clear)

 

This product is protected by one or more of the following U.S. Patents and their 

foreign counterparts: 6,016,038, 6,150,774, 6,292,901, 6,340,868, 6,777,891, 

6,788,011, 6,806,659, 6,969,954, and 6,975,079. Other patents pending.

©2002-2007 Color Kinetics Incorporated. All rights reserved. Chromacore, Chromasic, 

CK, the CK logo, Color Kinetics, the Color Kinetics logo, Color Kinetics The Leader in 

Intelligent Light, ColorBlast, ColorBlaze, ColorBurst, ColorCast, ColorPlay, ColorScape, 

DIMand, Direct Light, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, 

Light Without Limits, Optibin, Powercore, QuickPlay, Sauce, the Sauce logo, and 

Smartjuice are either registered trademarks or trademarks of Color Kinetics Incorporated 

in the United States and/or other countries.

PUB-000143-00 Rev. 03

Specifications subject to change without notice. Refer to www.colorkinetics.com for the 

most recent version.

ColorBlast  6

u s e r

 

g u i d e

CANOPY BASE

LIQUID-TIGHT

FITTING

O-RING

CABLE

DOME NUT

Fig. 1

Отзывы: