background image

IntroductIon

Color Kinetics® ColorBlast® 12 Powercore marries Color Kinetics' 

popular ColorBlast 12 with Powercore™ technology. This combi-

nation offers wall-washing, wall-grazing, spot lighting and large 

alcove lighting in an easy-to-install, Powercore-based fixture. 
This guide contains important information on planning, installing, 

and operating your new ColorBlast 12 Powercore. For your protec-

tion, read it carefully and save it for future reference. 

Included In this Box

•  ColorBlast 12 Powercore

•  (2) 8-32 screws for indoor installations

• (4) 10-24 stainless steel screws for outdoor installations

•  (1) 3/32" hex key wrench

• User Guide

Additional Items needed

•  4” 

Electrical junction box (rated for your application) with 3.5” 

center-to-center distance for mounting locations. Refer to the man-

ufacturer's literature for additional items required for mounting or 

sealing. 

•  Data Enabler (Item# 106-000003-04/05) 

•  Controller - Color Kinetics or DMX compatible

• Light addressing tool: Color Kinetics Zapi (Item# 103-000005-00, 

US/103-000005-01, EU

) or Serial Addressing Software (SAS) with 

iPlayer 2 or Smart Jack 3

• 12 AWG, 4 conductor, copper wire
• Conduit and hubs as required

optional Items

• 

 3/16" OD braided safety cable and hardware as required.

Scope of this user Guide

The goal of this user guide is to explain in an easily understood 

language the necessary steps to install ColorBlast 12 Powercore 

and assure peak performance. Its intended use is for reference only, 

by persons who are fully qualified. This document should never be 

considered a substitute for any provisions of a regulation or state and/

or local code.

Identification and Warnings of Safety Hazards

In accordance with ANSI Z535.4-2002, the following system 

identifies the severity of the hazards associated with the products:

danger

”  Imminently hazardous situation which, if not avoided, 

will result in death or serious injury.

warning

” Potentially hazardous situation which, if not avoided, 

could result in death or serious injury.

caution

”  Potentially hazardous situation which, if not avoided, 

may result in minor or moderate injury or property dam-

age. Also used to alert against unsafe practices.

ignoring

 

a

 

hazard

 

will

 

void

 

any

 

warranty

danger

: Ensure that main power supply is off before installing or 

wiring, ColorBlast 12 Powercore.  

danger

: ColorBlast 12 Powercore must be installed by a qualified 

electrician in accordance with NEC and relevant local codes. 

warning

: Do not attempt to install or use ColorBlast 12 Powercore 

until you read and understand the installation instructions, and 

safety labels.  

warning

: Do not use ColorBlast 12 Powercore if the lens, housing, 

or power cables are damaged.  

warning

: As dictated by a Structural Engineer and/or local 

code, install safety cables to ColorBlast 12 Powercore fixtures. 

warning

: When using safety cables, ensure that they comply to the 

specifications given in this user guide. 

warning

: ColorBlast 12 Powercore has line voltage risk of shock 

and no user serviceable parts. Do not attempt to open the fixture. 

caution

: Use appropriate materials and mounting methods to 

support the fixture adequately. 

caution

: Do not exceed the specified voltage and current input. 

caution

: Do not exceed the maximum number of specified fixtures 

in a light run. 

caution

: Do not use sharp tools near or on the fixture lens. 

caution

: Do not hot swap. Ensure that power to the fixture is off 

before connecting or disconnecting fixtures. 

caution

: ColorBlast 12 Powercore is a Class 2 LED product with 

LED radiation. Do not stare into beam or view directly with optical 

instruments.

note

: The instructions and precautions set forth in this user guide 

are not necessarily all-inclusive, all conceivable, or relevant to all 

applications as Color Kinetics cannot anticipate all conceivable or 

unique situations.

owner/user responsibilities

It is the responsibility of the contractor, installer, purchaser, owner 

and user to install, maintain, and operate ColorBlast 12 Powercore 

in such a manner as to comply with all state and local laws, ordi-

nances, regulations, and the American National Standard Institute 

Safety Code.

PlAnnInG tHe InStAllAtIon

ColorBlast 12 Powercore installation requires planning to ensure a 

timely, successful installation with minimal complications and down 

time.  

Planning Suggestions

When planning a ColorBlast 12 Powercore installation, Color 

Kinetics suggests doing the following:
•  Consult an Electrical Inspector to review all wiring plans.
•  Refer to local and state codes for installation compliance.
• Create a Layout Plan drawing.
•  Create a Mapping Grid. Use this grid to record serial numbers 

for easy reference and addressing.

•  Consult Color Kinetics Application Engineering Services as need-

ed at [email protected].

•  Get detailed wiring diagrams and additional support from  

www.colorkinetics.com/support.

Installation considerations

• 

 the location of data enabler in relationship to lights.

 

The maximum distance that the Data Enabler can be located from 

the last fixture in a series, or each individual fixture in a home-run 

installation is 175 feet (53 m). The maximum total cable run is 

400 feet (122 m).

•  

calculate the number of fixtures per data enabler.

 Use 

the 

Configuration Calculator

 located at www.colorkinetics.com/

support/install_tool to calculate the number of fixtures you can put 

on a Data Enabler. The fixtures-to-Data Enabler ratio is determined 

by the parameters of your installation. Installation parameters 

include all or part of the following: line voltage, circuit load, 

voltage drop, and cable lengths.

•  

location of the fixture and method of attaching.

 

Mounting hardware is dictated by the mounting surface. Ensure 

that the hardware used is appropriate for the mounting surface. 

• 

 Install and wire the data enabler after installing 

colorBlast 12 Powercore fixtures.

 Refer to the Data Enabler 

Installation Guide.

StePS to A SucceSSful InStAllAtIon

1. Record serial numbers and identify fixtures as you unpack them.
2. Install the fixtures.
3. Install the Data Enablers.
4. Connect power and data from the Data Enabler to the fixtures.
5. Address the fixtures.

recording Serial numbers

1. As you unpack the fixtures record the serial numbers. 

Each ColorBlast 12 Powercore has a unique serial number 

programmed at the time of manufacture.

2. Write the serial numbers onto a Mapping Grid or use a bar code 

scanner along with Color Kinetics Serial Addressing Software to 

record each serial number.
Color Kinetics Serial Addressing Software and instructions are 

located at www.colorkinetics.com/support/downloads.

3. Using the Layout Plan, assign the fixture to a layout position in 

the installation.

4. Using a weatherproof label, identify the fixtures' installation 

positions based on the Layout Plan. Place the identifying label in 

an inconspicuous location noting the order or placement in the 

installation. This step not only minimizes installation mistakes, but 

aids in post-installation programming of your light shows.

Installing colorBlast 12 Powercore

ColorBlast 12 Powercore fixtures are junction box mounted. Ensure 

that the junction box used in your installation is suitable for the 

environment. 
ColorBlast 12 Powercore can be installed in a daisy-chained series 

or each fixture can be home-run to a common junction box.

 

 

through-Base cable Assembly

For all installations where the cable must go through the canopy 

base, follow the directions below to prevent cable damage and to 

create a water-tight seal for outdoor installations.
1. Screw the liquid-tight fitting into the canopy base. The O-ring 

must be seated against the canopy opening to ensure a water-

tight seal.

2. Insert the fixture cable through the dome nut. Loosen dome nut if 

necessary. Pull the cable through the fitting. Leave enough cable 

above the fitting to ensure full fixture head rotation.

3. Tighten dome nut to seal the cable. After 24 hours, tighten the 

dome nut again to ensure proper sealing force and water-tight 

seal. See Fig. 1.

daisy chain fixtures

1.  Pull 12AWG, 4-conductor, stranded copper wiring between 

junction boxes in a series. The maximum cable run from Data 

Enabler to the last fixture in a series is 175 feet (53 m).

2.  Trim fixture cable to fit in junction box leaving enough cable to 

make wiring connections. 

3. Use wire nuts to connect line (Black/Brown), neutral (White/

Gray), ground (Green/Yel), and data (Red/Black).

note

: For outdoor installations, insert fixture cable through 

junction box gasket before making wire connections.

4. Tuck wire connections into junction box and use provided screws 

to attach the fixture to the junction box. See Fig. 2.

note

: For outdoor installations, ensure that the gasket is 

compressed evenly for a water-tight installation.

Home run fixtures

1.  Pull 12AWG, 4-conductor, stranded copper wiring from Data 

Enabler to a common junction box, and from the common 

junction box to each fixture's junction box. The maximum cable 

run from Data Enabler to any fixture in a series is 175 feet  

(53 m), and the maximum total cable run is 400 feet (122 m).

2.  Trim fixture cable to fit in junction box leaving enough cable to 

make wiring connections. 

Color Kinetics Incorporated
10 Milk street, Suite 1100
Boston, MA 02108 USA
Tel 888 Full RGB
Tel 617 423 9999
Fax 617 423 9998
[email protected]
www.colorkinetics.com

IteM#  123-000005-00 (ul, White, frosted lens)

 

123-000005-01 (ul, Black, frosted lens)

 

123-000005-02 (eu, White, frosted lens)

 

123-000005-03 (eu, Black, frosted lens)

 

123-000005-04 (ul, White, clear lens)

 

123-000005-05 (ul, Black, clear lens)

 

123-000005-06 (eu, White, clear lens)

 

123-000005-07 (eu, Black, clear lens)

 

This product is protected by one or more of the following patents: U.S. Patent Nos. 6,016,038, 

6,150,774 and other patents listed at http://colorkinetics.com/patents/. Other patents pending.

©2005-2006 Color Kinetics Incorporated. All rights reserved. Chromacore, Chromasic, Color 

Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorCast, ColorPlay, 

ColorScape, Direct Light, iColor, iColor Cove, iPlayer, Optibin, Powercore, QuickPlay, Sauce, 

the Sauce logo, and Smartjuice are registered trademarks and DIMand, EssentialWhite, eW, 

IntelliWhite, iW, and Light Without Limits are trademarks of Color Kinetics Incorporated.

PUB-000130-00 Rev. 02

Specifications subject to change without notice.

ColorBlast 12 

Powercore

u s e r

 

g u i d e

Daisy Chain Connection

12AWG, 4-conductor Stranded Copper Cable From Data Enabler

Gasket

Maximum run length 

from Data Enabler 

to last fixture in series: 

175 feet (53 m)

Fig. 2

LOCK NUT

CANOPY BASE

CABLE

LIQUID-TIGHT

FITTING

O-RING

DOME NUT

Fig. 1

DRY

WET

DAMP

warning

:

 

When installing ColorBlast 12 Powercore fixtures, the 

input earth ground, canopy earth ground, and the fixture cable 

earth ground must all be connected together. Failure to make these 

connections could result is death or serious injury. 

Отзывы: