7.

 

Errors and Troubleshooting 

The troubleshooting tables in this Chapter will help you to determine whether you can troubleshoot yourself or whether you need to call 

customer service. 

 

IMPORTANT 

Jot down the serial number of the machine and the error code from the display before you call customer service. The machine's serial 

number is on the type plate. 

 

7.1

 

Possible errors 

Fault 

Description 

Machine condition 

Solutions 

E010 

Door open 

 

Door open 

 

Close door  

 

 

Door closed 

 

Check the door lock 

 

Check the power cord / plug to the door lock. 

E020 

EMERGENCY STOP 

activated 

 

EMERGENCY STOP button pushed 

 

Release the EMERGENCY STOP 

 

 

EMERGENCY STOP button not 

pushed 

 

Check the switch of the EMERGENCY STOP button 

 

Check the power cord / plug to the EMERGENCY STOP 

button. 

E050 

Defective container 

 

Container is defect 

 

Container is unstable 

 

Check  clamping pressure, if necessary adjust 

E070 

Mixing Unit locked 

 

Latching pin blocked 

 

The latching pin is blocked – clean and lubricate, 

replace if necessary 

 

 

Latching pin released 

 

Check the lead/connector to the switch of the mixing 

unit magnet 

 

The switch of the mixing unit magnet is defective

 

E080 

Mixing Unit unlocked 

 

Latching pin blocked 

 

The mixing unit is not 12 at o'clock position, see 

capter 6.5.1 

 

Check the lead/connector to the switch of the latching 

pin 

 

The switch of the latching pin is defective 

 

 

Latching pin released 

 

Check the lead/connector to the switch of the mixing 

unit magnet 

 

The switch of the mixing unit magnet is defective

 

E120 

Mixing speed too low 

 

The mixing unit rotates

 

 

Check the lead/connector to the "position" 

 

proximity switch 

 

The "position" proximity switch is defective

 

 

 

The mixing unit does not rotate

 

 

Check frequency converter 

 

Check the door safety switch 

 

Check the main motor

 

E130 

Mixing speed too high 

 

The mixing unit rotates too fast 

 

Decrease the motor speed

 

E150 

Error clamp motor 

 

The mixing container is not 

clamped 

 

Check the clamp motor 

 

Check the lines to the clamp motor 

 

Check the control 

 

 

 

Содержание Rota 400

Страница 1: ...Version G 1 5 18 Instructions Biaxial Mixer ROTA 400 Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch...

Страница 2: ...ROTA 400 Collomix GmbH D 85080 Gaimersheim 2 Version G 1 5 18...

Страница 3: ...10 5 1 Content 10 5 2 Transport 10 5 3 Set up the equipment 10 5 4 Trial run 10 6 Operation 11 6 1 Switching on the machine 11 6 2 Load a container 11 6 3 Starting the mixing cycle 12 6 4 Ending the...

Страница 4: ...omponents Machine components 1 Screw for transport roller 7 Manual door release 2 Line connector and main fuse 8 Control panel 3 Upper clamping plate 9 Door 4 Control system fuse 10 Lower clamping pla...

Страница 5: ...ersion G 1 5 18 5 1 2 Operating and display components Button for DOOR OPEN door Button E OPEN the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I Button II...

Страница 6: ...ntion to the corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautionary measures...

Страница 7: ...ase read these Operating Instructions before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent own...

Страница 8: ...ous with obvious malfunctions Repair cleaning and maintenance work without disconnecting the system from power WARNING Danger of injury through improper modifications Hazards exist through unauthorize...

Страница 9: ...ne if needed 3 6 Residual Risks If all precautions are taken there may be obvious residual risks Adhering to the safety instructions the designated use and the operating instructions as a whole can re...

Страница 10: ...machine the applicable electrical requirements and the additional information in this Operating Instructions must be followed The machine is delivered on a wooden pallet packaged in recyclable cardbo...

Страница 11: ...to work with it 6 1 Switching on the machine The machine is turned on using the main switch 5 After an automatic initialisation READY is shown on the display Any errors detected during initialisation...

Страница 12: ...tch In dangerous situations the machine can be turned off with the EMERGENCY STOP switch After the EMERGENCY STOP button is pressed the mixing unit will coast to a standstill and remain in this positi...

Страница 13: ...positioned and fixed with the help of Button I Auto 6 5 3 MANU With the mixing container unclamped the mixing unit must be positioned manually Upon actuation of Button III MANU the door can be opened...

Страница 14: ...e if necessary adjust E070 Mixing Unit locked Latching pin blocked The latching pin is blocked clean and lubricate replace if necessary Latching pin released Check the lead connector to the switch of...

Страница 15: ...of the door lock Check door motor E190 Fuse blown Turn the machine off and wait one minute until the fuse can be pushed in again The grey highlighted services can only be carried out by trained techni...

Страница 16: ...the threaded spindles and lubricate with Mobilux EP2 Check the timing belt for wear and tear Age conditioned lengthening of the timing belt is indicated by a twisted clamping plate 10 Elongating can...

Страница 17: ...ntentional tilting and instability 9 2 Disposal The transport package is made of recyclable material Please dispose this material accordingly At the end of the useful life the machine must be properly...

Страница 18: ...eter max 360mm Machine weight 215kg Dimensions w x d x h 780 987 1186mm Noise emission in accordance with 2006 42 EG Sound pressure level LpA 64dB re 20 Pa Sound power level LWA 75dB re 1pW Uncertaint...

Страница 19: ...ordance with the requirements of the guidelines 2006 42 EC 2004 108 EC 19 04 2016 2014 30 EU 20 04 2016 2011 65 EU Please request technical information from Collomix GmbH Abt Technische Entwicklung Da...

Страница 20: ...ROTA 400 Collomix GmbH D 85080 Gaimersheim 20 Version G 1 5 18 Collomix GmbH Daimlerstr 9 D 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de...

Отзывы: