BIAX
45P
Collomix GmbH
16
Version 1.7-18
7.3
Unlock door manually
The machine is equipped with a safety lock, which locks the door automatically after it is closed. In
the event of a malfunction or power outage, the door can be locked manually.
•
Disconnect the machine from the mains by pulling out the mains plug.
•
Remove the plastic stopper (5) from the door unlocking device.
•
Use a screwdriver to move the unlocking device in direction of the arrow.
•
Open the door.
WARNING
Risk of injury by machine parts that continue to rotate
When activating the manual door release, the mixing process is interrupted automatically. The
mixing unit will run for a few seconds up to a complete standstill.
•
Use the manually door unlocking device only in case of emergency.
•
Before using the manually door unlocking device, always disconnect the machine from the
mains by pulling out the mains plug.
•
Never use the manually door unlocking device whilst the mixing unit is turning.
7.4
Fuses on the device
7.4.1
Device fuse
If line voltage is available but the power button does not light up, the cause may be a faulty device
fuse.
The device fuse is located in the mains connection on the back of the machine. Only use 5x20mm,
230V/10AT fuses to replace a blown fuse.
If the device fuse is tripped again, there is a defect in the control unit. If this is the case, contact an
authorised service partner to correct the error.
7.4.2
DC fuse
If the power button is on, but nothing is showing on the display of the operating unit, the cause may
be a tripped DC fuse.
The DC fuse is located next to the power button. After the fuse is tripped, wait at least one minute,
and only then press the pin back in until it locks into place.
If the device fuse is tripped again, there is a defect in the control unit. If this is the case, contact an
authorised service partner to correct the error.
Door unlocking device
Device fuse
DC fuse