CWI 8076 V1

NOTE:

   The remote control will go to “sleep” mode after 15 seconds unused.  

Press the 

ON/OFF button to “wake up” the remote before any other operation.

Up to 8 remote controls can be set to operate a C100924 controller.  
A remote control will not operate a controller until they are set up as a pair. 

SET UP FOR SINGLE ZONE OPERATION

1.  Insert 3 x AAA batteries (not supplied) into the remote control.

2.  Switch on the power to the controller and power repeaters.

3.  Remove the terminal cover from the C100924 controller to access the learning switch (next to the 24V DC input).

4.  Press and hold down the learning switch until the LEDs flash (approx. 5 seconds).

5.  “Wake up” the remote control by pressing the ON/OFF button.

6.  Press the learning switch on the controller.

7.  Press 1 on the remote control to allocate Zone 1.

8.  Run a finger around the colour wheel until the LEDs start to change colour.
9.  The remote control can now be used to change colours, select cycles etc.
NOTE – If the set up does not work first time, repeat steps 5, 6, 7 and 8.

SET UP

 – Multiple Zones (up to 6)

To set a controller to Zone 2, follow the above process, but press 

2 in step 7. To set a controller to Zone 3, 4, 5 or 6, follow the 

above process, but press the appropriate Zone number in step 7.
To delete a zone setting, e.g. so it can be reset to another zone, press the learning button until the LEDs flash (approximately 5 
seconds).

OPERATION
ZONE NUMBERS:  

Press 1 to select Zone 1, and the remote control will operate all LEDs in Zone 1.

 

Similarly, press 2 for to operate LEDs in Zone 2 etc.

 

Press and hold 1 to switch off LEDs in Zone 1. Press and hold to switch on.

 

Similarly for Zones 2-6.

OPTIONS

For all operation options, select the Zone number first, then the following operations will be actioned in that zone.

RGBW

:  Press R to switch on red LEDs. Press again to switch off red LEDs. Press and hold dims LEDs up/down.

 

Operation method for blue, green and white is the same.

 

Note – if for example red LEDs are on and blue is switched on, the output colour will be purple. To go from red to blue, 
switch off red, then switch on blue.

 

White can be used in a colour mix to achieve pastel colours. For vivid colour mix, switch off or dim white

INCREASE/DECREASE MAX BRIGHTNESS:

  A maximum brightness level can be set, e.g. if 50% is set, LEDs will not exceed 50% 

brightness. Press and hold         to increase maximum brightness,         to decrease 
maximum brightness.

COLOUR WHEEL:

  Touch to activate colour.

CYCLE:

  There are ten pre-set cycles. Press the start/stop cycle button to activate a cycle, press again to stop the cycle, press 

again to go to cycle 2, etc.  
Press and hold the button to increase/decrease cycle speed.

ON/OFF:  

Press to switch ON/OFF all zones.

RETURN:  

Press return button once to return to previous mode.

SAVE:  

To save a colour or cycle in Zone 1, press 

1, then the colour or cycle required.

 

Press and hold the save button until the LED indicator turns blue. Immediately press 

1

The LEDs will flash to confirm a succesful save. 

 

The colour or cycle is saved in Zone 1, position 1.

 

To recall the colour/cycle, press 

1 (to select Zone 1), press S (to access the saved ones), then 1.

 

Save up to 6 colours or cycles in each Zone.

EN

EN

t  +44 (0) 1604 495 151  f  +44 (0) 1604 495 095 
e  [email protected]  w  collingwoodlighting.com

DE

FR

t  +33 (0) 4 816 816 10  f  +33 (0) 4 816 816 11 
e  [email protected]  w  collingwoodlighting.com

t  +49 (0)89 411123 777  f  +49 (0)89 411123 778 
e  [email protected]  w  collingwoodlighting.com

COLOUR WHEEL

INCREASE MAX BRIGHTNESS

CYCLE FASTER

DECREASE MAX BRIGHTNESS

START/STOP CYCLE

RED/GREEN/BLUE ON/OFF /

DIM UP/DOWN

WHITE LED ON/OFF

ON/OFF ALL ZONES

CYCLE SLOWER

SAVE

RETURN TO PREVIOUS MODE

ZONE NUMBERS / 

SAVED POSITION NUMBERS

LED INDICATOR

HAND HELD REMOTE CONTROL 

|

 TÉLÉCOMMANDE 

FERNBEDIENUNG

Instructions / Anleitung

PRI:

Uin=24VDC

lin=4A
SEC:

Uout=4x(24)VDC

Iout=4x1A

TEMP RANGE:-20°C-+50C

SIGNAL

 OUTPUT

Learning

Switch

xxxxxx

6-7mm

0.5-2.5mm

2

CWL 2409 V1

24V INPUT

LEARNING SWITCH