![Coherent Solutions SwitchBlade Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/coherent-solutions/switchblade/switchblade_user-manual_2634924015.webp)
Modular Optical Switch
|
SwitchBlade
Coherent Solutions
|
SwitchBlade
(V1.4)
11
8
Removing a SwitchBlade Expansion Module
W
ARNING
DO NOT
attempt to remove or adjust any component of the MTP1000 while the
power is on. Make sure you follow the correct procedures below and power down
the MTP1000 first.
C
AUTION
The SwitchBlade is sensitive to ESD. Please be sure to wear a grounded wrist
strap at all times when handling the SwitchBlade module to prevent such
damage.
Take care not to handle the connector on the SwitchBlade module once they
are exposed as this may leave corrosive residue which can damage the
connector.
I
MPORTANT
A Blanking module will be required to replace the removed SwitchBlade
module. Please make sure you have a blanking module available. The
specifications of the SwitchBlade are only valid when all empty slots have
blanking modules.
You will need antistatic packaging to store the SwitchBlade upon removal at
the appropriate step in the following installation procedures. Please make sure
this packaging is immediately available before continuing with the following
procedure.
Note
: You will need a Phillips and Slot screwdriver to both unfasten the SwitchBlade module and secure the
blanking module in place.
Acquire storage electrostatic packaging and blanking module
1.
In preparation for removal of the SwitchBlade module, locate and retrieve the antistatic packaging the
SwitchBlade was supplied in. This should have been stored near the MTP1000 when the SwitchBlade was
installed.
2.
Also you will require a
blanking module
to install once the SwitchBlade has been removed.
I
MPORTANT
Do not continue unless you have the
blanking module
and appropriate
storage packaging for the removed SwitchBlade. If the SwitchBlade is not
stored correctly it may be affected by ESD. The specifications of the
SwitchBlade are only valid when all slots have blanking modules.