Trigger Input
The I/O module provides inputs for triggering the In-Sight Micro or In-Sight 5000 series vision system (T or
TRIGGER -). When the I/O module is connected to the vision system, trigger input signals travel directly through the I/O
module and are optically isolated in the vision system. Trigger inputs are typically connected (directly or indirectly) to a
sensor (such as a photo-detector). Refer to
for common wiring configurations.
CAUTION
:
When connecting the In-Sight 7000 series vision system to the CIO-MICRO or CIO-MICRO-CC I/O
module, the I/O module's and TRIGGER- terminals are not supported. Do not connect wire leads from
remote devices to these terminals.
Specification
Description
Voltage
ON: 20 to 28VDC (24VDC nominal)
OFF: 0 to 3VDC (8VDC nominal threshold)
Current
ON: 5mA to 7.7mA
OFF: < 250μA
Resistance: ~3.5 kOhms
30