Connect the Power and I/O Breakout Cable
The Power and I/O Breakout cable must be used to supply power to the In-Sight 7000 series vision system. The Power
and I/O Breakout cable also provides access to the vision system's trigger, general-purpose inputs, high-speed outputs
and RS-232 communications. Refer to the
In-Sight
®
7000 Series Vision System Installation Manual
for more information.
Note
:
l
The power supplies for the vision system and I/O module can be combined into a single power supply,
provided the single power supply meets the capacity requirements of the two devices.
l
When the In-Sight 7000 series vision system is configured for use with the CIO-MICRO or CIO-MICRO-CC
I/O module, the RS-232 TRANSMIT and RS-232 RECEIVE pins on the Breakout cable are disabled. Use the
I/O module's RS-232 port (DB9) to connect to a serial device. Refer to
Connect an RS-232 Serial Cable
l
Unused wires can be clipped short or tied back using a tie made of non-conductive material.
1. Verify that the vision system's 24VDC power supply is unplugged and not receiving power.
2. Optionally connect the Power and I/O Breakout cable's I/O wires to an appropriate device (for example, a PLC).
Refer to the
In-Sight
®
7000 Series Vision System Installation Manual
for more information.
3. Attach the Breakout cable's +24VDC (Red wire) and GND (Black wire) to the corresponding terminals on the
power supply.
CAUTION
:
Never connect voltages other than 24VDC. Always observe the polarity shown.
4. Connect the Breakout cable's M12 connector to the vision system's PWR connector.
5. Restore power to the vision system’s 24VDC power supply and turn it on if necessary.
6. Restore power to the I/O module’s 24VDC power supply and turn it on if necessary.
7. Use In-Sight Explorer software to configure the vision system and I/O module. For more information, refer to the
In-Sight
®
Explorer Help
file, which is available from the Help menu or by pressing the F1 key.
24