Ethernet Cable
The Ethernet cable provides Ethernet connectivity to the vision system.
P1 Pin Number
Wire Color
Signal Name
P2 Pin Number
1
White/Orange
TxRx A +
1
2
Orange
TxRx A -
2
3
White/Green
TxRx B +
3
4
Blue
TxRx C +
8
5
White/Blue
TxRx C -
7
6
Green
TxRx B -
4
7
White/Brown
TxRx D +
5
8
Brown
TxRx D -
6
CAUTION
:
The Ethernet cable shield must be grounded at the far end. Whatever this cable is plugged into
(typically a switch or router) should have a grounded Ethernet connector. A digital voltmeter should be used to
validate the grounding. If the far end device is not grounded, a ground wire should be added in compliance with
local electrical codes.
Note
:
l
Cables are sold separately.
l
The wiring for this cable follows standard industrial Ethernet M12 specifications. This differs from the 568B
standard.