Connect the Inputs and Outputs (Optional)
The vision system’s I/O connector supplies connections for the acquisition trigger and high-speed outputs.
Note
: The vision system must be Online for the discrete inputs and outputs to function. Refer to the
In-Sight
®
Explorer Help
file for details on configuring the discrete input and output lines.
Option 1: Connect the Breakout Cable
CAUTION
:
A ferrite is included with the In-Sight 8405 vision system standard components. To reduce emissions,
the ferrite must be attached to the Breakout cable.
Note
:
l
I/O wiring or adjustments to I/O devices should be performed when the vision system is not receiving power.
l
The Ethernet cable should be unplugged or the PoE source powered down before making adjustments to
the connections at the far end of the Breakout cable.
l
Unused wires can be clipped short or tied back using a tie made of non-conductive material.
1. If installing the In-Sight 8405 vision system, attach the ferrite around the Breakout cable, adjacent to the strain
relief on the cable.
2. Connect the Breakout cable's M8 connector to the vision system's I/O connector.
3. Connect the trigger and high-speed I/O wires to an appropriate device (for example, a PLC, trigger sensor or
strobe light). For more information, refer to
16
Installation