In-Sight® 1400 I/O Expansion Module Installation and Reference Manual
15
3.2.2 Trigger Input
The 1400 I/O Expansion Module provides inputs for triggering a connected In-Sight sensor
(T, TRIGGER-). When the expansion module is connected to a supported
In-Sight sensor, trigger input signals travel directly through the expansion module and are
optically isolated in the sensor. Trigger inputs are typically connected (directly or indirectly)
to a sensor (such as a photo-detector).
Figure 3-2: Trigger Input
Table 3-3: Trigger Input Specifications
Specification
Description
Voltage
ON 3 - 28V (when connected to an In-Sight sensor)
OFF 0 - 12V
Current
6mA (when connected to an In-Sight sensor)
Nȍ
Nȍ
Nȍ
Output to
In-Sight Sensor
T
TRIGGER -
I/O Expansion
Module
Opto-isolator
InSight Sensor