Specifications
14
3.2
Input and Output Specifications
3.2.1 General Purpose Inputs
The 1400 I/O Expansion Module extends the capabilities of supported In-Sight vision
sensors by providing seven independent, general-purpose inputs (INPUT 1 - INPUT 7) that
can be used to trigger sensor events. General purpose inputs are optically isolated and are
typically connected (directly or indirectly) to a sensor (such as a limit switch, pressure
switch, or temperature switch). See
for common wiring configurations.
Figure 3-1: General Purpose Input
Note:
Since all inputs share a common ground (IN COMMON), all connected input devices
must be either current sinking or current sourcing.
Table 3-2: General Purpose Input Specifications
Specification
Description
Voltage
ON 10 to 30V (24V nominal)
OFF 0 to 8V
Current
ON >3mA
Delay
Module 1 ms (maximum delay due to the I/O module)
Total
1.4 ms (Time between an input state change and completion of serial transmission
to an In-Sight Sensor.)
Nȍ
ȍ
Nȍ
2XWSXWWR
,Q6LJKW6HQVRU
,1387
,1&20021
2SWRLVRODWRU
,2([SDQVLRQ0RGXOH
0LFURFRQWUROOHU
Содержание In-Sight 1400
Страница 1: ...In Sight Vision for Industry In Sight 1400 I O Expansion Module Installation and Reference Manual...
Страница 2: ......
Страница 4: ...Copyright Trademarks Patents ii...
Страница 6: ...Regulations Conformity iv...
Страница 8: ...Precautions vi...
Страница 12: ...List of Figures x...
Страница 14: ...List of Tables xii...
Страница 26: ...Installation 12...
Страница 36: ...Specifications 22...
Страница 42: ...Appendix A Configuring Discrete Inputs 28...
Страница 57: ......
Страница 58: ...In Sight 1400 I O Expansion Module Installation and Reference Manual www cognex com P N 597 0104 01...