background image

DataMan

®

260 Series

Quick Reference Guide

2021 May 26
Revision: 6.1.10-SR1.4

Содержание DataMan 1AA0

Страница 1: ...DataMan 260 Series Quick Reference Guide 2021May26 Revision 6 1 10 SR1 4...

Страница 2: ...wer surges or other irregularities in the power supply l Changes or modifications not expressly approved by the party responsible for regulatory compliance could void the user s authority to operate t...

Страница 3: ...l This product does not contain user serviceable parts Do not make electrical or mechanical modifications to product components Unauthorized modifications can void your warranty 3...

Страница 4: ...tes a hazard that could cause death serious personal injury or electrical shock CAUTION This symbol indicates a hazard that could result in property damage Note This symbol indicates additional inform...

Страница 5: ...escription 1 Illumination LEDs 2 LED aimers 3 4 Mounting holes M3 x 3 5mm 5 Trigger button 6 Power indicator 7 Train status indicator 8 Good bad read indicator 9 Network status indicator 10 Error indi...

Страница 6: ...RS ILLUMINATIONS AND FILTERS Accessory Name Accessory Number Accessory Image 6 2 mm lens kit DM150 LENS 62 IR 6 2 mm lens kit 3 position with IR LED DMA KIT IR 62 IR 16 mm lens kit DMA KIT IR 16 16 mm...

Страница 7: ...ed DM260 LENS 16CVR DM260 LENS 16CVR P DM260 LENS 16CVR F C mount adaptor IP40 DM260 CMNT 00 C mount adaptor IP65 DM260 CMNT CVR Blue bandpass filter DM150 BP470 Red bandpass filter DM150 BP635 Red LE...

Страница 8: ...Connection cable RS 232 CCB M12xDB9Y 05 Adapter cable M12x12 to M8x4 M8x5 0 5 m DM260 ADAP M12M8 X Coded to RJ45 Ethernet Cable CCB 84901 2001 xx where xx can be 02 05 10 15 or 30 indicating length in...

Страница 9: ...Dimensional Drawings The size of the DataMan 260 in the angled configuration is shown in the following figures 9...

Страница 10: ...10...

Страница 11: ...The size of the DataMan 260 with the extended lens cover configuration is shown in the following figures 11...

Страница 12: ...12...

Страница 13: ...The size of the DataMan 260 with the side read mirror configuration is shown in the following figure 13...

Страница 14: ...eld of View values Device 1 2 3 4 DM260 Short Range 34 mm 1 3 in Short Range 50 mm 1 9 in Short Range 77 mm 3 0 in Long Range 115 mm 4 5 in DM262 Short Range 37 mm 1 45 in Short Range 56 mm 2 2 in Sho...

Страница 15: ...in Long Range 170 mm 6 7 in Long Range 279 mm 10 9 in Long Range 370 mm 14 5 in DM262 Long Range 153 mm 6 0 in Long Range 181 mm 7 1 in Long Range 297 mm 11 7 in Long Range 394 mm 15 5 in Vertical Fie...

Страница 16: ...Range 28 mm 1 1 in Short Range 42 mm 1 65 in Short Range 65 mm 2 5 in Long Range 92 mm 3 6 in 5 6 7 8 DM260 Long Range 92 mm 3 6 in Long Range 108 mm 4 25 in Long Range 178 mm 7 0 in Long Range 236 m...

Страница 17: ...in mm 1D min code 6 2 mm lens Long Range DM260 150 12 MIL 150 6 MIL 190 15 MIL 190 10 MIL 225 18 MIL 225 10 MIL 375 30 MIL 375 15 MIL 500 35 MIL 500 20 MIL 1000 80 MIL 1000 35 MIL DM262 150 10 MIL 15...

Страница 18: ...mm 2D min code 6 2 mm lens Short Range Distances in mm 1D min code 6 2 mm lens Short Range DM260 40 4 MIL 40 2 MIL 65 5 MIL 65 3 MIL 105 10 MIL 105 6 MIL DM262 40 3 MIL 40 2 MIL 65 4 MIL 65 2 MIL 105...

Страница 19: ...n code 16 mm lens DM260 80 3 MIL 80 2 MIL 150 5 MIL 150 3 MIL 190 6 MIL 190 4 MIL 225 7 MIL 225 4 MIL 375 12 MIL 375 5 MIL 500 15 MIL 500 10 MIL 1000 25 MIL 1000 15 MIL DM262 80 2 MIL 80 2 MIL 150 3 M...

Страница 20: ...DataMan 260 Readers with Side Read Mirror The following table shows the Field of View FoV widths of DM260 with 6 2 mm lens focused to 190 mm at various distances 20...

Страница 21: ...Device 1D min code Distance in mm Width in mm DM260 10 MIL 196 158 13 MIL 261 205 15 MIL 305 237 18 MIL 370 285 20 MIL 414 316 21...

Страница 22: ...the Field of View FoV widths of DM262 with 6 2 mm lens focused to 190 mm at various distances Device 1D min code Distance in mm Width in mm DM262 10 MIL 327 269 13 MIL 431 350 15 MIL 501 404 18 MIL 6...

Страница 23: ...he reader 2 Connect the Ethernet cable CCB 84901 2001 05 either to a computer or a switch 3 Connect the breakout cable CCBL 05 01 For information on the pinout and wire colors see section Connections...

Страница 24: ...on Note l Cables are sold separately l If a standard component is missing or damaged immediately contact your Cognex Authorized Service Provider ASP or Cognex Technical Support CAUTION All cable conne...

Страница 25: ...made of non conductive material to tie them back 1 Verify that the 24VDC power supply is unplugged and not receiving power 2 Attach the Breakout cable s 24VDC and GROUND to the corresponding terminals...

Страница 26: ...network 3 Connect the cable to a 24V power supply To configure a DataMan 260 reader the DataMan Setup Tool software must be installed on a networked PC The DataMan Setup Tool is available from the Da...

Страница 27: ...8 2 6 vibration test in each of the three main axis for 2 hours 10 Gs 10 to 500 Hz at 100m s2 15mm LED Safety IEC 62471 Exempt risk group no further labeling is required RS 232 RxD TxD according to TI...

Страница 28: ...power supply no PoE 24 VDC 10 1 A maximum 5 W average Supplied by LPS or NEC class 2 only Power Consumption 3 84 W PoE Class 1 5 W average externally powered at 24 V DataMan 260 Series Imager Specifi...

Страница 29: ...ptional liquid lens with IR blocking filter S mount 16 mm F 7 with optional liquid lens with IR blocking filter LED Wavelengths The following table shows LED types and the related wavelengths LED nm R...

Страница 30: ...Subpart B Class A This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accep...

Страница 31: ...noted within the 2014 30 EU Electromagnetic Compatibility Directive For further information please contact Cognex Corporation One Vision Drive Natick MA 01760 USA Cognex Corporation shall not be liab...

Страница 32: ...the pressure on the natural resources we encourage you to use the appropriate take back systems for product disposal Those systems will reuse or recycle most of the materials of the product you are di...

Страница 33: ...nyls PBB Polybrominated diphenyl ethers PBDE Regulatory Models 1AA5 1ABD 1AA0 1ABF X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 SJ T 11364 O Indicates that said h...

Страница 34: ...Copyright 2021 Cognex Corporation All Rights Reserved...

Отзывы: