23
9.8
Error messages
If a malfunction occurs,
LEDko T/D Studio
has a self-diagnostic system that will show the er-
ror message on the display. The following table will explain in detail the most common errors. If,
despite of suggested intervention, the problem persists, call the
Coemar
Service Center.
9.7
Special functions of the fixture
Storing the DMX signal
To use the fixture without an active DMX console it is possible to store the DMX settings in two
ways:
• Through the
TEST
menu
;
•
Disconnecting the DMX signal when the fixture is on. When the signal is unconnected the
fixtures stores the signal;
Automatic fan standby
To decrease the noise and the power consumption the cooling fan turns off after 10 minutes of
fixture inactivity.
Error code
Description
noal
[No Alarm]
No alarm
The projector self-diagnostic routine didn’t find any issue.
DTER
[Data Error]
Data error
Initial data loading has failed the projector loaded the default
data settings: restart the fixture again, and if the error persists
contact the
Coemar
assistance center.
ADER
[Address Error]
Address error
The projector does not receive all channels of DMX needs to
function properly. Check the DMX address indicated on the dis
-
play and the number of channels generated by the mixer con-
trol. We recall in this connection that some controllers do not
generate all the 512 channels.
LEd
[LED Error]
LED error
Auto diagnostic routine found that the LED module may dam
-
aged, contact Coemar assistance for the module replacement.
IMPORTANT:
To ensure the sensor is giving correct readings,
set the LED to the maximum light output level.