English
3) Select the operating voltage from the 100, 115, 208, 230 and 245V options by moving the cable n° 7 to the required
voltage. To ensure correct positioning of the cable, refer to the label located on the transformer.
4) If the voltage is altered to either 100 or 115V replace the current fuse rated at 5 Amps T, which is suitable for 208/230/245
V, with a fuse rated at 8 Amps T. The fuse holder is located on the side of the base of the unit. The reverse should be
undertaken if the voltage is being increased to the latter range.
5) Proceed to the selection of the proper frequency, as described in the following section, and then replace the cover and
refasten the screws (A).
16.2 Selecting the frequency on the power supply of the ProSpot LX
1) Locate the power supply (A) locate in the base of the unit.
2) Select the required frequency from between 50 and 60Hz by moving cable n° 11 to the correct option. To ensure correct
positioning of the cable, refer to the label located on the power supply.
4) Replace the cover and refasten the screws (
A
).
5AT @230V
8AT @115V