Control signal is digital and is transmitted via two pair screened ø0.5mm cable as per international standards for the transmission of
DMX512 data. Connection is serial, utilising XLR 3 male and female sockets located on the base of the
ProSpot 575 MB,
labeled
DMX
512 IN
and
OUT
(see diagram).
Plug/socket connections for XLR3
connectors:
Pin connections conform to the international standard as per the following table:
pin 1 = GND
pin 2 = data -
pin 3 = data +
If using a controller which output signal via an XLR 5 (5 pin) socket, do not use pins 4 and 5, leave them unconnected.
ATTENTION!!
Ensure that all data conductors are isolated from one another and the metal housing of the connector.
Pin number 1 should never be connected to the device’s power supply.
lamp: 575W MH
type: MSR/2
or MSD
base: GX 9,5
max temp ext:
150
°
C
2 m
2 m
ta max:
35
°
C
230V
ie: 3,5A
ie max: 5A
il: 6,95A
IP 20
cos
ϕ
0,98
115V
ie: 7A
ie max: 10A
serial number:
made in italy
by
coemar
spa,
Castel Goffredo
Mantova - Italy
factory set
main at:
100V
115V
208V
230V
240V
50Hz
60Hz
T2A @230V
T3A @115V
T5A @230V
T12A @115V
Power
in
out
pin1: gnd
pin2: data–
pin3: data+
dmx 512
lamp: 575W MH
type: MSR/2
or MSD
base: GX 9,5
max temp ext:
150
°
C
2 m
2 m
ta max:
35
°
C
230V
ie: 3,5A
ie max: 5A
il: 6,95A
IP 20
cos
ϕ
0,98
115V
ie: 7A
ie max: 10A
serial number:
made in italy
by
coemar
spa,
Castel Goffredo
Mantova - Italy
factory set
main at:
100V
115V
208V
230V
240V
50Hz
60Hz
T2A @230V
T3A @115V
T5A @230V
T12A @115V
Power
in
out
pin1: gnd
pin2: data–
pin3: data+
dmx 512
3
2
1
Controller
Standard
DMX 512
OUT
out
in
Ad altri
ProSpot 575 MB
Connect to other
ProSpot 575 MB
out
in
6. DMX signal connection
9
English