Panorama C
yc 1800
A
rchitectural
utilises a Philips 1800 MSI 1800W lamp with a SFc 15,5 lampbase.
The lamp is available from your authorised
coemar sales agent
:
coemar cod.
105808
power
1800 w
luminous flux
155000 lm
colour temperature
5600° K
base
SFc 15,5
approximate lamp life
3000 hours
The fixture’s internal temperature can reach 250° C after 5 minutes, with a maximum peak of 350° C; ensure that the lamp
is cold prior to attempting removal. The fixture should be allowed to stand and cool for 10 minutes prior to its removal.
MSI lamps are part of the mercury vapour family of discharge lamps and must be handled with great care. The lamp opera-
tes at high pressure, and the slight risk of explosion of the lamp exists if operated over its recommended life of 500 hours.
We recommend, therefore, that the lamp be replaced within the manufacturer’s specified lamp life.
installing the lamp
1) Using a Philips head screwdriver, remove the 14 screws (A)
which affix the rear housing (B) to the body of the projector.
2) Using the attached handle remove the rear housing (B) of
the projector, to which the lamp assembly is attached.
3) Remove the lateral reflectors (C) by removing the 4 screws
(D).
Attention!
Remove mains power prior to opening up the unit.
4. Lamp: installation and replacement
English