4) Insert the lamp
The lamp used is manufactured from quartz glass and should be handled with care; always adhere to the instructions supplied in
the lamp’s packaging. Never touch the glass directly, use the tissue provided in the lamp’s packaging. The GX 9,5 lampbase is
symmetrical in construction. DO NOT USE UNDUE FORCE. In case of difficulty, re-read the instructions and repeat the procedure.
5) Replace the lamp assembly and replace and tighten the screws (
A
) which were previously removed.
Attention:
we recommend that the lamp be realigned in the optical train of the unit to avoid overheating of the dichroic filters and
other internal components of the unit. refer to section
13
for instructions about this procedure.
The projector may operate at voltages including 100, 115, 208, 230 or 240 V.
coemar
presets (barring specific requests) a voltage of
240v.
The preset voltage is indicated on a sticker located on the base of the projector near the position of the voltage selector switch.
ISPOT 575 EB
may operate at either 50 or 60 Hz without any changes required.
selecting an operating voltage different to the factory preset
It is possible to alter the operating voltage of the projector at any time. See section
15. Altering the operating voltage
An error in voltage selection may cause serious damage to the projector.
factory set
main at:
100V
115V
208V
230V
240V
50Hz
60Hz
5. Operating voltage and frequency