ISPOT 575 EB
utilises a Philips 575 MSD or a Philips 575 MSR/2 lamp at 575 watts with a GX 9,5 lamp base. The lamp is availa-
ble from your authorised
coemar
sales agent.
The fixture’s internal temperature can reach 250° C after 5 minutes, with a maximum peak of 350° C; ensure that the lamp is cold
prior to attempting removal. The fixture should be allowed to stand and cool for 10 minutes prior to its removal. MSR/SA lamps are
part of the mercury vapour family of discharge lamps and must be handled with great care. The lamp operates at high pressure,
and the slight risk of explosion of the lamp exists if operated over its recommended life of 1000/3000 hours. We recommend, there-
fore, that the lamp be replaced within the manufacturer’s specified lamp life.
installing the lamp
1) Using a Phillips head screwdriver, remove the screws (
A
) which hold the lampholder assembly in place, located at the rear of the
projector head.
2) Remove the lampholder assembly (
B
)
3) Locate the lampholder (
C
)
Attention
Turn off mains power prior to opening up the unit
Philips 575 MSD
coemar cod.
105215
power
575 w
luminous flux
43.000 lm
colour temperature
6000° K
base
GX 9,5
approximate lamp life
3000 hours
Philips 575 MSR/2
coemar cod.
105245/2
power
575 w
luminous flux
49.000 lm
colour temperature
7.200° K
base
GX 9,5
approximate lamp life
1000 hours
4. Lamp: installation and replacement