If the factory preset operating voltage and frequency do not correspond to those in use in your country of operation, you may alter
the settings as described in the following paragraphs.
Incorrect selection of operating voltage and frequency will seriously compromise the functioning of the pro-
jector.
19.1. Selecting the transformer voltage
1) Loosen the screws on the cover of the base of the unit, as shown in the diagram below, using a Philips head screwdriver, the-
reby removing the cover completely and allowing access to the internal components of the base of the
ISPOT 575 EB.
2) Locate the autotransformer in the base of the unit.
3) Select a voltage from amongst 100, 115, 208, 230 and 240V
by removing cable n° 5 and moving it to the required voltage.
To determine which is the correct tap, refer to the sticker loca-
ted on the autotransformer.
Cable number 3 should not be moved under any circumstan-
ces.
4) If the operating voltage selected is 115V replace the 5 Amps T,
and the 2 Amps T fuses,suitable for 208/230/240 V, operation
with ones rated respectively at 12 Amps T and 3 Amps T in the
fuse holder in the base of the projector and vica versa (see
label). Replacement fuses of suitable ratings were provided in
the packaging of your fixture with this manual.
6) Note on the sticker on the outside of the
ISPOT 575 EB
the new voltage which you have selected.
3) Close up the base with the housing covers as they were originally.
4) Note on the sticker on the outside of the
ISPOT 575 EB
the new voltage which you have selected.(as shown in the diagram)
factory set
main at:
100V
115V
208V
230V
240V
50Hz
60Hz
T2A @230V
T3A @115V
T5A @230V
T12A @115V
19. Altering the operating voltage (reserved for technical personnel)
English