Operation and Maintenance 

 

Issue: A 

Revision:1 

Date:07/01/19 

Ref:100542 

 

 

 

 

 

 

 

 

 

 

 

 

TunnelTech 602  

Illuminance Monitor 

Operation and Maintenance Manual 

 

 

 

 

 

 

 

 

CODEL International Ltd

Station Building, Station Road, Bakewell, Derbyshire DE45 1GE United Kingdom  

t : +44 (0) 1629 814 351      f : +44 (0) 8700 566 307      e : [email protected]       web : www.codel.co.uk 

 

 

Содержание TunnelTech 602

Страница 1: ...7 01 19 Ref 100542 TunnelTech 602 Illuminance Monitor Operation and Maintenance Manual CODEL International Ltd Station Building Station Road Bakewell Derbyshire DE45 1GE United Kingdom t 44 0 1629 814...

Страница 2: ...CODEL Page 2 Operation and Maintenance Issue A Revision 1 Date 07 01 19 Ref 100542...

Страница 3: ...s set standards both for itself and for the rest of the industry All development and design work is carried out in house by experienced engineers using proven state of the art CAD and software develop...

Страница 4: ...CODEL Page 4 Operation and Maintenance Issue A Revision 1 Date 07 01 19 Ref 100542...

Страница 5: ...f Operation 3 3 Specification 4 Technical Data 4 Construction and Enclosure 4 Output and Interface 4 Compliance and Certification 5 Cables 5 Installation Materials 5 4 Installation 6 Device dimensions...

Страница 6: ...CODEL Page 6 Operation and Maintenance Issue A Revision 1 Date 07 01 19 Ref 100542...

Страница 7: ...low are used throughout these instructions and are intended to ensure your safety while carrying out installation operation and maintenance procedures Please read these instructions fully before proce...

Страница 8: ...CODEL Page 8 Operation and Maintenance Issue A Revision 1 Date 07 01 19 Ref 100542...

Страница 9: ...e luminaries in the tunnel entrance interior and exit The TunnelTech 602 is designed in accordance with Commission Internationale de l Eclairage C I E publication 88 1990 recommendations Tunnel lighti...

Страница 10: ...ontrolled heater to prevent fogging of the glass and allow the device to function at temperatures down to 20 C The glass fibre reinforced polyester enclosure used to house the TunnelTech 602 is tested...

Страница 11: ...us sending near constant updated information via a 4 20mA output The output of the photocell is fed into a low noise chopper stabilised amplifier with further stages provide current limiting dark curr...

Страница 12: ...20 000 lux Accuracy 3 Response Time Instantaneous Path Length N A Ambient Temperature 20 C to 50 C Humidity 0 100 R H Storage Temperature 40 C to 75 C Power Supply Nominal Voltage Optional as 10 to 3...

Страница 13: ...Optional Tunnel Regulation Guidelines RABT 2006 RVS 09 02 22 2007 and any others Cables Power Supply Cable 110V AC 240V AC 10 to 35V DC Minimum Specification Specified by region 2 Core 1mm Typically S...

Страница 14: ...00542 4 Installation CAUTION Device installation must be performed by specialist technical staff only Device dimensions Figure 3 TunnelTech 602 Dimensions 129 75mm 120mm 248mm Mounting plate supplied...

Страница 15: ...To open the enclosure to access the mounting holes and the power input and signal output terminals unscrew the 4 corner screws located on the top or lid of the device using a suitable screwdriver Care...

Страница 16: ...lden Type 8771 or its equivalent Insert the electrical and signal cables through the cable glands and make the necessary connections to the clearly marked POWER and SIGNAL screw terminals making sure...

Страница 17: ...ly or as specified No auxiliary current supply is necessary When electrical connections have been made to power and signal connections carefully replace the lid making sure the lid gasket is in place...

Страница 18: ...Power Supply Unit PSU Installation Mount the PSU to the mounting surface using 4 M6 bolts by others Mounting hole details are shown in Figure 7below Figure 7 Optional PSU mounting Arrangement Make su...

Страница 19: ...rmally necessary within ten year periods Maintenance Minimal Occasional cleaning of the viewing window is required When cleaning the sensor window avoid ethyl alcohol solvents hydrogenated hydro carbi...

Страница 20: ...sponse from the sensor is perfectly linear within the measuring range of 0 to 20 000 lux and therefore the Ma output is delivered accordingly and is updated near constantly Figure 8 lux to mA output g...

Страница 21: ...igures Figure 1 TunnelTech 602 1 Figure 2 Tunnel Luminance Curve Graph 1 Figure 4 TunnelTech 602 Dimensions 6 Figure 5 mounting dimensions 7 Figure 6 Electrical Schematic 8 Figure 7 Electrical Termina...