5 - Voltage Level: The voltage variance for remote start when set to tachless.
(see tach mode)

HIGH - The variance in battery voltage from before the remote start
is activated to after the engine is running must be greater than 0.5 volts.

LOW - The variance in battery voltage from before the remote start
is activated to after the engine is running may be less than 0.5 volts.

6 - Crank Time: Preset output times for the PURPLE starter wire.

1 Second

0.8  Seconds

     1.5 Seconds

 2 Seconds     4 Seconds

7 - Crank Average / Crank Time: The length of time in which the remote start
will crank the vehicle’s starter.

Crank Average - Determines crank time by averaging the last 8 times the
vehicle was started with the key.

Preset Time - Preset starter output time. (see crank time)

8 - Gas / Diesel: Selects engine type and delay time for the starter output wire
during remote start activation.

Gas - Gasoline engine, no delay for the starter output wire.

10 Second Delay - Diesel engine, delays the starter output wire for 10
seconds after the ignition has been powered up by the remote start.

15 Second Delay - Diesel engine, delays the starter output wire for 15
seconds after the ignition has been powered up by the remote start.

20 Second Delay - Diesel engine, delays the starter output wire for 20
seconds after the ignition has been powered up by the remote start.

45 Second Delay - Diesel engine, delays the starter output wire for 45
seconds after the ignition has been powered up by the remote start.

9 - Single / Double Pulse Start: Switches the remote start activation between
a single or double press from the transmitter.

10 - IGN 2 Output: Programmable high current output.

Ignition 2 - Ignition output during remote start.

Accessory - Accessory output during remote start.

Start / Crank - Crank output during remote start.

11 - 2 or 3 Hour Start: When activated, the remote start will activate and run for
the programmed time and shut down every 2 or 3 hours.

Содержание ca 4552

Страница 1: ...1 ca4552 2011Audiovox Electronics Corporation All rights reserved PROFESSIONAL SERIES Remote Start Installation Guide ca 4552...

Страница 2: ...oor Lock Output Harness 10 Additional Ports 11 Antenna LED Programming Port 11 DBI Port 11 Telematic Interface Port 11 Set Up Programming 12 Transmitter Programming 12 Manual Feature Programming 12 Pr...

Страница 3: ...near hot surfaces Avoid mounting components or routing wires near moving parts Tape or loom wires under hood for protection and appearance Technical Support 800 421 3209 or go to http techservices cod...

Страница 4: ...3 Pin Parking Light Harness 1 LT GREEN BLACK FACTORY DISARM PULSE BEFORE START 2 LT BLUE FACTORY ARM PULSE AFTER START 3 GREEN WHITE PULSE AFTER SHUTDOWN 4 BLACK YELLOW PULSE DURING CRANK 4 PIN ALTERN...

Страница 5: ...owing diagram Use an SPDT relay not supplied Ignition 3 output see the following diagram Use an SPDT relay not supplied Accessory 2 3 output see the following diagram Use an SPDT relay not supplied Fu...

Страница 6: ...l increase as the engine s RPM increases Connect the PURPLE WHITE wire to the negative side of the vehicle ignition coil or fuel injector 3 GRAY HOOD PIN INPUT Install a Hood Pin Switch and connect to...

Страница 7: ...K wire with any other vehicle components 3 Pin Parking Light Harness 2 WHITE RED PARKING LIGHT INPUT 3 WHITE PARKING LIGHT OUTPUT Locate the parking light output wire at the vehicle s light switch Ver...

Страница 8: ...constant 12 Volt battery wire NOTE Remove all fuses until all connections are made 3 ORANGE ACCESSORY 1 Locate the vehicle s accessory wire at the ignition switch Verification This wire registers vol...

Страница 9: ...wire to the constant 12 Volt battery wire NOTE Remove all fuses until all connections are made 4 Pin Alternate Output Harness 1 LT GREEN BLACK FACTORY DISARM PULSE BEFORE START This wire will supply...

Страница 10: ...86 85 BLAC K YE LLOW P ulse During C rank Wire To Vehicle s2nd S tarter Wire Jump To P UR P LE S tarter Output Wire From The C ontrol Module 2 Pin Lock Output Harness 1 BLUE UNLOCK The door unlock ou...

Страница 11: ...t Supervision Transponder Interface Activation Factory Alarm Arm Disarm Manual Arm Disarm Inputs factory keyless controls system Antenna Port Mount the supplied antenna receiver to a clear spot on the...

Страница 12: ...n is on there is no time limit To exit programming turn the IGNITION OFF Set Up Programming Transmitter Programming Feature Bank 1 1 Turn the ignition ON 2 Press and hold the valet override button 3 W...

Страница 13: ...LED Flash 1 Extended Lock Pulse 1 Second 3 5 Seconds Double Pulse Unlock Feature Bank 5 7 Chirps 4 Pin Alternate Output Control 1 LED Flash 2 LED flash 3 LED Flash 4 LED Flash 5 LED Flash 6 LED Flash...

Страница 14: ...nses the tach signal the parking lights will begin to flash 6 Allow the vehicle to settle to a normal idle speed 7 Release the valet program push button switch The parking lights will stay on solid in...

Страница 15: ...of the transmitter or system shutdowns 3 Running Lights Controls the WHITE parking light output wire during remote start Steady Parking lights constant during the remote start cycle Flashing Parking l...

Страница 16: ...put wire during remote start activation Gas Gasoline engine no delay for the starter output wire 10 Second Delay Diesel engine delays the starter output wire for 10 seconds after the ignition has been...

Страница 17: ...ce and has confirmed the vehicle is running Also a 1 second pulse when unlock is pressed Ground While Running Continuous output for the entire remote start sequence until after the vehicle shuts down...

Страница 18: ...es active with the same timing as the starter output wire during crank only Ground While Running Continuous output for the entire remote start sequence until after the vehicle shuts down Ignition Outp...

Страница 19: ...e patterns below indicating the shutdown input To manually enter diagnostics and view the last shutdown turn the ignition ON and press and hold the button for 3 seconds LED FLASHES SHUTDOWN ZONE 3 Fla...

Страница 20: ...K YELLOW PULSE DURING CRANK BLUE UNLOCK OPEN PURPLE STARTER OUTPUT MOTOR SIDE RED BATTERY 12V ORANGE ACCESSORY 1 PINK WHITE IGNITION 2 RED WHITE BATTERY 12V PINK IGNITION 1 BLACK GROUND WHITE RED PARK...

Страница 21: ...21 ca4552 2011Audiovox Electronics Corporation All rights reserved...

Страница 22: ...les and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received in...

Отзывы: