136.01.1706.UG

Jun 29, 2017

Antenna Pattern Measurement Helper

One to Two Weeks in Advance

    Make sure you have all equipment needed Transponder, GPS, whips.

    

Check transponder battery & charge > 12 volts (a new battery will be > 13 volts when fully 

charged)

Day of APM

    Synchronize the computer to GPS clock and confirm site and antenna are functioning 

properly

    Quit all applications except SeaSondeController and SeaSondeAcquisition
    Stop logging cross spectra, checkmark “Enable Loop Diagnostics”

CONFIGURE RECEIVER 

    Use SeaSondeController menu Receiver Controller->Receiver APM Configuration

or

    STORE receiver’s normal operating settings in AWG register 3 (in SEND box: type save 3, 

press enter key)

     CONFIGURE RECEIVER with APM Settings as follows and then store the settings in AWG 

register 2:

Configure  Transponder

    Connect USB cable between XPNDR and Mac laptop and launch SeaSonde Transponder 

Application

    Configure TRANSPONDER by clicking “INITIALIZE” button in SeaSonde Transponder 

application

SeaSonde 

Model

Bandwidth

Blanking

Bdly  

µ

s

Attenuation 

Boat/Walking

Sweep  

Frequency

Pulse 

Shaping

5MHz

25kHz

120

~4.75

15/30db**

2Hz

Off

12MHz

50kHz

60

~4.75

15/30db**

4Hz

Off

25Mhz

150kHz

60

~4.75

15/30db**

8Hz

Off

42MHz

150kHz

60

~4.75

15/30db**

8Hz

Off

Antenna Pattern Measurement Helper