background image

4-Stroke Engine

INVERTER GENERATOR

USER MANUAL

Model

IG

2

0SI

Содержание IG20SI

Страница 1: ...4 Stroke Engine INVERTER GENERATOR USER MANUAL Model IG20SI...

Страница 2: ...tor Cobra will continuously innovate and develop its products both in design and quality The content of this manual may have minor difference from the updated product Please contact your supplier for...

Страница 3: ...CONTENT 22 22 23 25 26 28 30 31 32 33 04 06 08 08 09 10 10 11 12 13 15 17 18 19 20 20 07 33 34 36 Hourmeter...

Страница 4: ...r To ensure personal and property safety please carefully read the following information 04 WARNING distance with constructions and other electrical appliances at least Place the generator on the leve...

Страница 5: ...05 SAFETY LABEL...

Страница 6: ...06 2 SAFETY LABLE LOCATIONS...

Страница 7: ...07 CHOKE KNOB FUEL CAP VENT LEVER FUEL CAP AIR CLEANER MAINTENANCE COVER STARTER GRIP CONTROL PANEL SPARK PLUG MAINTENANCE COVER MUFFLER 3 C IDENTIFICATION OMPONENTS FUEL SWITCH ENGINE SWITCH ECON SW...

Страница 8: ...tate automatically when the electrical appliance is disconnected and it will return to the proper speed with the requirement of electrical load ON OFF ECON SW DC Circuit Protector DC Receptacle Ground...

Страница 9: ...C load and DC load turn the economy control switch to the OFF position NOTE For protection condition the output indicator light green is off and the overload indicator light red is on Every starting t...

Страница 10: ...heck Oil Level NOTE Using non detergent or 2 stroke oil could shorten the engine s working life Using the high quality engine oil with strong detergents Using 4 stroke engine oil certified to meet or...

Страница 11: ...ixture Avoid getting dirt or water into the fuel tank Do not use a mixture Petrol containing ethanol or methanol otherwise it will seriously damage the engine Fuel Capacity 3 6L OPEN FUEL CAP UPPER LI...

Страница 12: ...remove the cover c Check the element clean or replace it if necessary NOTE Do not run engine without the air cleaner element Operating the generator without the filter will damage the engine Check the...

Страница 13: ...eceptacle 5 1 Turn the fuel cap vent lever to the ON position OFF O N ON FUEL CAP VENT LEVER NOTE When transporting generator turn the fuel cap vent lever to the OFF position 5 2 Turn fuel switch to t...

Страница 14: ...the starter grip slowly until it is engaged then pull it quickly NOTE Return the starter grip slowly by hand Do not make the starter grip spring back quickly 5 6 Push the choke knob to the original p...

Страница 15: ...zle or adjust the idling screw of carburetor If the generator always operates at altitude above WARNING If the carburetor has been modified for high altitude operation the air fuel mixture will be too...

Страница 16: ...erators Do not connect an extension to the exhaust pipe When an extension cable is required be sure to use a tough rubber sheathed flexible cable according to IEC245 or equivalent standards The maxmin...

Страница 17: ...nals with the charging cable CAUTION Connect red lead to positive battery terminal and black lead to negative battery terminal 6 1 3 Turn ECON SW to OFF position and then start engine Disconnecting th...

Страница 18: ...circuit overload will trip the DC DC RECEPTACLE DC CIRCUIT PROTECTOR 4 Reconnect the vehicle battery ground cable The battery can release the explosive gases Keep the battery away from spark fire Cha...

Страница 19: ...9 NOTE Confirm all electrical appliances are in good working condition before connecting them to the generator If an electrical appliance becomes abnormal sluggish or stops suddenly shut off the gener...

Страница 20: ...t down the engine the engine switch remains in the ON position If the oil alert system shuts down the engine the oil alert indicator light red will be on Check the engine oil level OIL ALERT INDICATOR...

Страница 21: ...OFF position OFF O N FUEL CAP VENT LEVER OFF NOTE Be sure the fuel cap vent lever and engine switch locate the OFF position when stopping transporting and storing the generator 7 3 Turn the fuel switc...

Страница 22: ...over and remove the cover 8 1 2 Remove the oil filler cap 8 MAINTENANCE The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition WARNING Stop the...

Страница 23: ...g to the environment requirement the used oil will be put into a sealed container and then be transported to the service station for recycler Do not throw it into the trash or pour it on the ground 8...

Страница 24: ...ow ignition point solvents for cleaning They are flammable and explosive under certain conditions NOTE Never run the generator without the air cleaner rapid damage to the engine will occur 8 2 1 Loose...

Страница 25: ...park plug 8 3 1 Remove the spark plug maintenance cover SPARK PLUG MAINTENANCE COVER 8 3 2 Take off the spark plug cap 8 3 3 Clean the carbon deposition at the bottom of the spark plug HANDLE BAR SPAR...

Страница 26: ...er A used Spark plug should be tightened 1 8 to 1 4 turn with spanner 8 3 8 Reinstall the spark plug cap 8 3 9 Reinstall the spark plug maintenance cover NOTE The spark plug must be securely tightened...

Страница 27: ...park arrester from the muffle after the engine cool down 8 4 3 Use a brush to remove carbon deposits from the spark arrester If the spark arrester is wear replace it 8 4 4 Reinstall the spark arrester...

Страница 28: ...enerator should be used under a good ventilated condition Avoid exposing directly in the sunshine when the generator place in the enclosed transport vehicle for a long time The high temperature inside...

Страница 29: ...clean engine oil 10 20ml into the cylinder Revolve the engine several times to distribute the oil and reinstall the spark plug 9 5 Pull the starter grip slowly until feel resistance At this point the...

Страница 30: ...obra dealer Is the fuel cap vent lever ON Is the choke knob pull out NO NO NO NO NO Stop engine and then replace or repair the appliance Restart the engine DC receptacle without any electricity Is the...

Страница 31: ...A Noise LpA Dimensions L W H Net Weight WorkingAmbientTemperature OTHER SPECIFICATIONS Noise level is measured when the ECON SW is turned to ON L shows the guaranteed sound power wA tested by 2000 14...

Страница 32: ...12 WIRING DIAGRAMS 32 Aux Winding Main Winding CDI Generator Oil Sensor Spark plug CDI Ignition AC Receptacle To Reset Hourmeter DC Receptacle Engine Switch Igniter Stepter Motor ECON SW Reset...

Страница 33: ...0 93 0 91 0 89 0 87 0 84 0 87 0 85 0 82 0 80 0 78 0 75 0 73 0 71 0 69 0 66 0 64 0 62 0 60 0 58 0 56 0 54 0 52 0 50 0 48 0 46 0 500 1000 2000 3000 4000 Ambient temperature Factor of environment correc...

Страница 34: ...whether or not further precautions are required Factors that influence the actual level of exposure of work force include the characteristics of the 13 2 Noise and Access Example Rated power P 1 6kVA...

Страница 35: ...ne Displacement 79 cm3 Rated Output Power 1 6 kVA Max 2 0 kVA Measured sound power level 68 dB A Guaranteed sound power level 90 dB A Notified Body for EC Directive 2000 14 EC 0499 T V Rheinland LGA P...

Страница 36: ...ealer who is professionally trained to complete service work as necessary The Cobra dealer list is available at cobragarden co uk or contact 0115 986 2161 for assistance When contacting your dealer pl...

Страница 37: ...Cobra Garden Machinery Henton and Chattell Ltd London Road Nottingham NG2 3HW UK...

Отзывы: