Metapace L-42DT User Guide
VIF
8/20
© IZUM, 30. 11. 2016, VIF-NA-BG-128, V2.0
Media calibration is required when the printer is installed for the first time, when changing the
label format and when the printer does not print in the designated printing space (print
positioning is off).
How to run media calibration:
1.
Enter manual calibration mode: when the printer is on, hold the PAUSE button for two
seconds. Both LED indicators change colour from green to orange.
2.
The colours of the LED indicators start to change and the required operation (i.e.
calibration) is started when pressing the FEED button (LED 1 is orange, LED blinks
green four times).
To learn more about calibration, consult the original user manual, chapter "5. Detailed features",
page 20.
2.5.4.1
Media calibration with the use of the enclosed tool
Procedure:
1.
Connect the printer via the desired interface (serial, USB or Ethernet).
2.
Run “Unified Label Utility-II.exe” from the enclosed CD or download it from the
website
2
.
3.
Select the installation interface and click the "Connect" button.
Figure 4: Unified Label Utility-II tool
2
http://www.jarltech.de/2007/support.php?gotoartikel=metapace_l-
42dt&sort=kategorie&language=en&kat_id=2200&link=2&supportdata=metapace_l-42dt-en