Interfaces of the SAILOR 900 VSAT High Power ACU
4-2
Chapter 4: Interfaces
98-150471-A02
4.1.2
ADU connector
There is just one cable from the ACU to the ADU. This is used to power the ADU, supply
10 MHz clock, handle all communication between ACU and ADU, and deliver the VSAT Rx
and Tx signals.
4.1.3
Rx/Tx connectors for VMU
Connect the Rx and Tx channels of the VMU to the Rx and Tx connectors of the ACU with
the 2 supplied Rx/Tx cables (75 Ohm coax, F-F, 1 m).
For step-by-step guidelines how to set up the VSAT modem see
Outline
(on the ACU)
Conductor
Pin function
Inner
DC to ADU
10 MHz clock to ADU
ACU to ADU internal
communication
VSAT Rx/Tx
Outer
GND (Shield)
Table 4-1: N connector, outline and pin assignment
Important
Do not use TNC connectors on the ADU antenna cable
or on pigtails. TNC connectors cannot carry the DC
current for operating the ADU.
Outline
(on the ACU)
Pin
number
Pin function
1
Inner conductor:
10 MHz clock, VSAT Rx/Tx
2
Outer conductor: GND (Shield)
Table 4-2: F connector, Rx and Tx, outline and pin assignment
SAILOR900HP.book Page 2 Monday, July 18, 2016 12:44 PM
Содержание SAILOR 900
Страница 1: ...SAILOR 900 VSAT High Power Installation manual...
Страница 141: ...Appendices SAILOR900HP book Page 1 Monday July 18 2016 12 44 PM...
Страница 142: ...SAILOR900HP book Page 2 Monday July 18 2016 12 44 PM...
Страница 194: ...Linkway S2 modem C 36 Appendix C VMU settings 98 150471 A02 SAILOR900HP book Page 36 Monday July 18 2016 12 44 PM...
Страница 208: ...E 4 Appendix E DVB S satellites 98 150471 A02 SAILOR900HP book Page 4 Monday July 18 2016 12 44 PM...
Страница 232: ...CE R TTE H 2 Appendix H Approvals 98 150471 A02 SAILOR900HP book Page 2 Monday July 18 2016 12 44 PM...
Страница 245: ...98 150471 A02 www cobham com satcom...