Separate ground cable
F-10
Appendix F: Grounding and RF protection
98-133966-G1
F.6
Separate ground cable
F.6.1
Ground cable - construction
When dealing with electrical installations in a marine environment, all
wiring must be done with double insulated, tinned strands, high quality
and if exposed also UV resistant cables. This shall also apply to the
separate ground cable mentioned in the previous paragraphs.
The ground cable is constructed using an appropriate cable with a cross
section area of at least 6 mm
2
(AWG10) and terminated with insulated
ring crimp terminals – see illustration below. The crimp terminals must
be a marine approved type e.g. the DuraSeal series from Raychem.
Figure F-6: Separate ground cable
$QWHQQD
0,QVXODWHG5LQJ7HUPLQDO
5D\FKHP'XUD6HDO6HULHV
7HUPLQDO
$SSURSULDWHVL]H
,QVXODWHG5LQJ7HUPLQDO
5D\FKHP'XUD6HDO6HULHV
SAILOR900TM.book Page 10 Monday, September 16, 2013 11:01 AM
Содержание Sailor 900 VSAT
Страница 2: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 2 15 04 2013 15 54 39 ...
Страница 16: ...Table of contents xiv 98 133966 G1 SAILOR900TM book Page xiv Monday September 16 2013 11 01 AM ...
Страница 28: ...List of tables xxvi 98 133966 G1 SAILOR900TM book Page xxvi Monday September 16 2013 11 01 AM ...
Страница 257: ...Appendices SAILOR900TM book Page 1 Monday September 16 2013 11 01 AM ...
Страница 258: ...SAILOR900TM book Page 2 Monday September 16 2013 11 01 AM ...
Страница 338: ...CE R TTE H 2 Appendix H Approvals 98 133966 G1 SAILOR900TM book Page 2 Monday September 16 2013 11 01 AM ...
Страница 340: ...Eutelsat S A H 4 Appendix H Approvals 98 133966 G1 SAILOR900TM book Page 4 Monday September 16 2013 11 01 AM ...
Страница 354: ...Index 10 Chapter Index 98 133966 G1 SAILOR900TM book Page 10 Monday September 16 2013 11 01 AM ...
Страница 355: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 3 15 04 2013 15 54 40 ...
Страница 356: ...98 133966 G1 www cobham com satcom 98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 4 15 04 2013 15 54 40 ...