Chapter 3: Connect the system
Connect power
37
3333
Co
nn
ec
t th
e
sy
st
em
29 VDC operation:
Examples of max. cable lengths in meters for different
cable types and source impedance.
Note
Remember that the total max. cable length from the mini-C to the
last unit on the CAN bus
must never exceed 200 m
! See
Supply Voltage
29 VDC
Source imp. in mOhm >
0
50
100
200
mOhm/m
AWG 11
4.13
200
a
200
a
200
a
200
a
AWG 12
5.21
200
a
200
a
200
a
200
a
AWG 13
6.57
200
a
a. This is not the calculated length, but the max. CAN cable length from the
mini-C to the last unit on the CAN bus. You must take into consideration the
length of the cable from the T-connector to the power supply (max. 6 m),
and the length of cables from the mini-C to the last unit on the CAN bus
(max. 200 m).
199
195
188
AWG 14
8.29
161
158
155
149
AWG 15
10.45
128
125
123
118
AWG 16
13.17
101
99
97
94
AWG 17
16.61
80
79
77
74
AWG 18
20.95
64
62
61
59
AWG 19
26.42
50
50
49
47
AWG 20
33.31
40
39
39
37
Table 5: Max. cable length in meters for 29 VDC operation
Содержание SAILOR 6120
Страница 1: ...SAILOR 6120 30 40 50 Installation manual...
Страница 2: ......
Страница 3: ...i SAILOR 6120 30 40 50 Installation manual Document number 98 154541 A Release date November 15 2017...
Страница 12: ...List of tables x...
Страница 31: ...Chapter 2 Install the system Install the SAILOR 3027 19 2222 Install the system Vertical pole Horizontal pole...
Страница 96: ...Chapter 5 Installation check and test 84 Test the system with SAILOR 6018...
Страница 116: ...98 154541 A www cobham com satcom...