GR740-UM-DS, Nov 2017, Version 1.7
202
www.cobham.com/gaisler
GR740
Table 218.
0x00000008 - RTR.PNPDEVID - SpaceWire Plug-and-Play - Device ID
31
0
DID
0x00000000
cas
31: 0
Device ID (DID) - Shows the device identifier. After reset / power-up, or when this field is written to zero, the
router is not considered to have an owner. The same applies to the case when the port indicated by the OL bits in
the Link Information field is either disconnected, or disabled by setting the RTR.PCTRL.DI bit to 1. This field is
only writable through a compare-and-swap operation.
Table 219.
0x00000009 - RTR.PNPUVEND - SpaceWire Plug-and-Play - Unit Vendor and Product ID
31
16 15
0
VEND
PROD
0x0000
0x0000
r
r
31: 16
Unit vendor ID (VEND) - Shows the unit vendor identifier. This field is read-only through the SpaceWire Plug-
and-Play protocol, however it is writable through RMAP and AHB (see section 13.5.3). When this field, or the
PROD field, is written with a non-zero value, the U bit in the Link Information field is set to 1.
15: 0
Unit product ID (VEND) - Shows the unit product identifier. This field is read-only through the SpaceWire
Plug-and-Play protocol, however it is writable through RMAP and AHB (see section 13.5.3). When this field, or
the VEND field, is written with a non-zero value, the U bit in the Link Information field is set to 1.
Table 220.
0x0000000A - RTR.PNPUSN - SpaceWire Plug-and-Play - Unit Serial Number
31
0
USN
0x00000000
r
31: 0
Unit serial number (USN) - Shows the unit serial number. This field is read-only through the SpaceWire Plug-
and-Play protocol, however it is writable through RMAP and AHB (see section 13.5.3).
Table 221.
0x00004000 - RTR.PNPVSTRL - SpaceWire Plug-and-Play - Vendor String Length
31
15 14
0
RESERVED
LEN
0x00000
0x0000
r
r
31: 15
RESERVED
14: 0
Vendor string length (LEN) - Constant value of 0, indicating that no vendor string is present.