List of events
98-165591-B
Appendix B: System messages
B-2
BBBB
B.2
List of events
B.2.1
Events from Base Unit
Event ID
Severity
Description
Explanation
08060-0
WARNING Antenna modem ACU/Antenna communication error detected (framing and
parity). If the situation is persistent, check if cable
specifications comply (length and attenuation).
08063-0
ERROR
Antenna
connection
The ACU has lost connection with the antenna.
08064-0
ERROR
ADM PLL lock
The intermediate frequency PLL is not in lock. Check the
external reference signal.
08065-0
WARNING GNSS data
Missing GNSS data (fix).
08066-0
WARNING Heading data
Missing heading information. Check cable and heading
provider device.
08067-0
ERROR
PCB temperature ADM temperature too high. Make sure there is compliance
with the environmental specifications.
08068-0
ERROR
PSM power
The PSM fails to provide the requested supply voltage.
08069-0
WARNING Blocking Zone
The antenna has entered a blocking zone.
0806A-0
WARNING VMU connection The ACU has lost connection to the satellite modem.
0806C-0
ERROR
VMU frequency
setup
There is a mismatch in the frequency setup. Probably the
satellite modem is not configured correctly to match the
requirements of the ACU and antenna. A common
mismatch is the absence of Rx or Tx LO parameter in the
satellite modem.
0806D-0
ERROR
Antenna power
The antenna supply voltage is outside the allowed limits.
This may happen if the PSM fails to provide the requested
supply voltage.
0806E-0
ERROR
VMU reference
signal
There is no VMU Rx or Tx reference signal. Whether this is
Rx or Tx reference depends on the user's selection on the
modem profile page in the web interface. Make sure the
VMU Rx/Tx cable is connected and that the VMU is
configured to output the RX/TX reference signal.
0806F-0
WARNING ROSS
synchronization
The ACU has become out of sync with the ROSS device,
most likely because the ACU has been replaced, or the
ROSS satellite profile is new. A manual (forced) handoff
sequence must be initiated from the ROSS, refer to the
ROSS manual.