2201R Mobile Tester SCPI Reference Guide
Chapter 9 Call commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
169
:CALL:GSM:MSINfo:ALL
Syntax
:CALL:GSM:MSINfo:ALL
Parameters
There are no parameters.
Description
This command reads out all MS Info result values with one query.
The query delivers back 16 single values in the following sequence, all separated by commas:
- RX Lev (Integer) The mobile estimates the RF power level at which it receives the base station.
- RX Qual (Integer) Based on the number of bits corrected by its own channel decoder, the mobile estimates the BER.
- Number (String) This position contains the number dialed on the mobile. In case the call was BS originated, this
position is left empty (i.e. two consecutive commas in the result string).
- IMSI (String) This is the international mobile subscriber identity.
- IMEI (String) This position contains the international mobile equipment identity.
- MS Class GSM (Integer) Shows the mobile‘s power class for the GSM 900 band.
- Rev. Level (Integer) This parameter indicates whether the mobile supports all features of GSM phase 1 or phase 2
or any later phase.
- RX Lev Sub (Integer) Similar to RX Lev, but only carried out on a subset of frames.
- SMS (Boolean) A 0 on this position means that the mobile under test has no SMS capabilities, while a 1 indicates
that the mobile can handle SMS.
- Ext. Freq (Boolean) A 0 on this position means that the mobile under test cannot use the extended GSM frequency
range (E-GSM), while a 1 indicates that the mobile is able to work in the extended GSM frequency range.'
- A5 Cyph. (Integer) This position shows the A5 ciphering key supported by the mobile.
- Timing Advance (Integer) Here, the timing advance of the mobile is shown in bit periods.
- Dualband (Integer) A 6 on this position indicates that the mobile under test supports both the E-GSM and GSM 1800
(PCN) bands.
- MS Pwr (Integer) Here, the power control level currently used by the mobile is shown.
- EFR (Boolean) A 0 on this position means that the mobile under test cannot use enhanced full rate TCHs, while a 1
indicates that the mobile is capable of doing so.
- MS Class PCN/PCS(Integer) Shows the mobile‘s power class for the GSM 1800/1900 band.
Query
There is only a query form of this command available. The query returns a string containing 16 values coded as
explained above.
Example
:CALL:GSM:MSINfo:ALL?
The string delivered back is, for example:
"49,0,"+4989996410","001010123456789",
"520040190000430",4,2,49,1,0,3,0,1,16,1,2".